Device type · MSS
Folders And Injectors, Intraocular Lens (Iol)
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
MSS
Ophthalmic
Device class
Class I
FDA decisions since 2015
21
510(k), De Novo and PMA
Adverse event reports
436
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Folders And Injectors, Intraocular Lens (Iol)
- Product code
- MSS
- Device class
- Class I
- Review panel
- Ophthalmic
- Regulation
- 21 CFR 886.4300
- Specialty
- Ophthalmology
- FDA record
- Classification database entry for MSS
Latest FDA decisions
The 8 newest of 21 since 2015.
K261174 · Decided Jun 10, 2026 · 62 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
K252540 · Decided Sep 16, 2025 · 35 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
K242389 · Decided Oct 10, 2024 · 59 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
K231106 · Decided Sep 19, 2023 · 153 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
K231838 · Decided Aug 15, 2023 · 54 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
- RxSight Insertion Device510(k)
K231466 · Decided Jun 12, 2023 · 24 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
K212039 · Decided Aug 23, 2021 · 54 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
K200057 · Decided Jun 4, 2020 · 143 days after receipt
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS) · Ophthalmology
Reports received
436
Received Nov 1, 2025 to Nov 19, 2026. Includes 1 of another or unstated type.
Malfunction reports
368
84% of reports
Injury reports
67
15% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 26 | 4 | 0 | 0 |
| Jan 24 | 19 | 4 | 0 | 0 |
| Feb 24 | 15 | 14 | 0 | 0 |
| Mar 24 | 30 | 1 | 0 | 0 |
| Apr 24 | 38 | 6 | 0 | 0 |
| May 24 | 27 | 3 | 0 | 0 |
| Jun 24 | 23 | 5 | 0 | 0 |
| Jul 24 | 17 | 10 | 0 | 0 |
| Aug 24 | 7 | 7 | 0 | 0 |
| Sep 24 | 27 | 5 | 0 | 0 |
| Oct 24 | 20 | 3 | 0 | 0 |
| Nov 24 | 25 | 2 | 0 | 0 |
| Dec 24 | 61 | 6 | 0 | 0 |
| Jan 25 | 42 | 4 | 0 | 0 |
| Feb 25 | 36 | 6 | 0 | 0 |
| Mar 25 | 54 | 4 | 0 | 0 |
| Apr 25 | 48 | 7 | 0 | 0 |
| May 25 | 50 | 4 | 0 | 0 |
| Jun 25 | 23 | 7 | 0 | 0 |
| Jul 25 | 23 | 5 | 0 | 0 |
| Aug 25 | 21 | 2 | 0 | 0 |
| Sep 25 | 21 | 3 | 0 | 0 |
| Oct 25 | 18 | 5 | 0 | 0 |
| Nov 25 | 16 | 3 | 0 | 0 |
| Dec 25 | 29 | 5 | 0 | 0 |
| Jan 26 | 36 | 2 | 0 | 0 |
| Feb 26 | 54 | 2 | 0 | 0 |
| Mar 26 | 39 | 3 | 0 | 0 |
| Apr 26 | 46 | 10 | 0 | 0 |
| May 26 | 31 | 6 | 0 | 0 |
| Jun 26 | 41 | 13 | 0 | 0 |
| Jul 26 | 22 | 13 | 0 | 0 |
| Aug 26 | 11 | 3 | 0 | 0 |
| Sep 26 | 25 | 4 | 0 | 0 |
| Oct 26 | 18 | 3 | 0 | 1 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
- Rxsight32
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Device Damaged by Another Device153
- Crack106
- Scratched Material55
- Adverse Event Without Identified Device or Use Problem38
- Insufficient Device Problem Information37
- Material Twisted/Bent28
- Defective Component19
- Difficult to Advance14
- Break12
- Inaccurate Delivery9
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions199
- Insufficient Information186
- Endophthalmitis21
- Capsular Bag Tear16
- Hypopyon13
- Visual Impairment11
- Corneal Edema8
- Eye Injury6
- Inflammation6
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available5
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Rayner Intraocular Lenses Limited
Z-1753-2020 · Started Mar 17, 2020
Reason given: RaySert PLUS RSP01 LOT K030 labeled with an expiry of 2024-01 contained an inner tray that was labeled with an expiry of 2015. In addition to having an expiry of 2015 the LOT number on the inner tray is identified as V001.
Cause as FDA categorized it: Labeling mix-ups
Z-0071-2018 · Started Sep 1, 2017
Reason given: The recommended storage temperature on the label is incorrect.
Cause as FDA categorized it: Error in labeling
Z-2098-2017 · Started Apr 5, 2017
Reason given: Complaints concerning kinked haptics that were occurring during lens delivery.
Cause as FDA categorized it: Device Design
Z-0978-2017 · Started Sep 5, 2016 · Posted by FDA Jan 9, 2017
Reason given: The intraocular lens could become lodged within the cartridge
Cause as FDA categorized it: Device Design
Z-1156-04 · Started Aug 18, 2003 · Posted by FDA Jul 23, 2004
Reason given: Values for ApoB were not properly assigned on the package insert. Customers were not able to recover the analyte within the stated values.
Cause as FDA categorized it: Other
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.