436
Received Nov 1, 2025 to Nov 19, 2026. Includes 1 of another or unstated type.
Malfunction reports
368
84% of reports
Injury reports
67
15% of reports
Death reports
0
0.0% of reports
Reports received per month
product code MSS. By the date FDA received each report, stacked by event type. The newest month is incomplete, and FDA adds reports for recent months as it processes them.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Nov 25 | 16 | 3 | 0 | 0 |
| Dec 25 | 29 | 5 | 0 | 0 |
| Jan 26 | 36 | 2 | 0 | 0 |
| Feb 26 | 54 | 2 | 0 | 0 |
| Mar 26 | 39 | 3 | 0 | 0 |
| Apr 26 | 46 | 10 | 0 | 0 |
| May 26 | 31 | 6 | 0 | 0 |
| Jun 26 | 41 | 13 | 0 | 0 |
| Jul 26 | 22 | 13 | 0 | 0 |
| Aug 26 | 11 | 3 | 0 | 0 |
| Sep 26 | 25 | 4 | 0 | 0 |
| Oct 26 | 18 | 3 | 0 | 1 |
| Nov 26 | 0 | 0 | 0 | 0 |
Device types with the most reports
By FDA product code. A report that names several devices counts once for each.
Manufacturers with the most reports
Bigger sellers get more reports. This is not a ranking of safety.
- Rxsight32
Brand names with the most reports
As written on the reports. One product can appear under several spellings.
436 reports
Showing 1 to 25, newest first. Each title opens FDA's full record, which includes the reporter's description of the event.
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02150 · Received Oct 29, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
0001313525-2026-00170 · Received Oct 29, 2026 · Event dated Sep 30, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Insufficient Device Problem Information
Patient problem as coded: Endophthalmitis; Hypopyon; Visual Impairment; Eye Pain
0001313525-2026-00171 · Received Oct 29, 2026 · Event dated Sep 30, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Insufficient Device Problem Information
Patient problem as coded: Endophthalmitis; Hypopyon; Visual Impairment; Eye Pain
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02148 · Received Oct 28, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: Insufficient Information
- EyeGility InserterInjury
0001313525-2026-00165 · Received Oct 28, 2026 · Event dated Sep 28, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Adverse Event Without Identified Device or Use Problem
Patient problem as coded: Vitreous Loss; Capsular Bag Tear
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02140 · Received Oct 27, 2026 · Event dated Sep 18, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Break
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
Alcon Research, LLC - Alcon Precision Device
2523835-2026-01059 · Received Oct 26, 2026 · Event dated Oct 8, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Device Damaged by Another Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
Alcon Research, LLC - Alcon Precision Device
2523835-2026-01041 · Received Oct 22, 2026 · Event dated Oct 1, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Product Quality Problem; Device Damaged by Another Device
Patient problem as coded: Insufficient Information
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02115 · Received Oct 22, 2026 · Event dated Sep 15, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Device Damaged by Another Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02104 · Received Oct 21, 2026 · Event dated Sep 21, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Scratched Material
Patient problem as coded: Insufficient Information
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02105 · Received Oct 21, 2026 · Event dated Sep 21, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Scratched Material
Patient problem as coded: Insufficient Information
- RxSight Insertion DeviceMalfunction
3012712027-2026-00443 · Received Oct 19, 2026 · Event dated Sep 21, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Insufficient Device Problem Information
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02073 · Received Oct 15, 2026 · Event dated Sep 22, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
MW6003840 · Received Oct 13, 2026 · Event dated Oct 6, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Entrapment of Device; Material Rupture; Failure to Align
Patient problem as coded: Insufficient Information
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02054 · Received Oct 12, 2026 · Event dated Sep 16, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- RxSight Insertion DeviceMalfunction
3012712027-2026-00428 · Received Oct 12, 2026 · Event dated Sep 14, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Insufficient Device Problem Information
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02015 · Received Oct 7, 2026 · Event dated Apr 24, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack; Device Damaged by Another Device
Patient problem as coded: Insufficient Information
Alcon Research, LLC - Alcon Precision Device
2523835-2026-01000 · Received Oct 7, 2026 · Event dated Sep 3, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Device Damaged by Another Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH IOL Delivery System, CartridgeMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02012 · Received Oct 6, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: Insufficient Information
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02002 · Received Oct 4, 2026 · Event dated Sep 8, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Particulates; Device Damaged by Another Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-02001 · Received Oct 2, 2026 · Event dated Sep 8, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Particulates; Device Damaged by Another Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-01981 · Received Oct 1, 2026 · Event dated Sep 1, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
Alcon Research, LLC - Alcon Precision Device
2523835-2026-00983 · Received Sep 29, 2026 · Event dated Aug 27, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Material Twisted/Bent
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- Easy-Load Lens Delivery SystemMalfunction
0001313525-2026-00152 · Received Sep 29, 2026 · Event dated Aug 31, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Material Split, Cut or Torn
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MONARCH III IOL Delivery System, Cartridge DMalfunction
Alcon Research, LLC - Huntington
1119421-2026-01968 · Received Sep 28, 2026 · Event dated Sep 2, 2026
Device type: Folders And Injectors, Intraocular Lens (Iol) (MSS)
Device problem as coded: Crack
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.