PMA device
Aneurx Stent Graft System
Medtronic Vascular · System, Endovascular Graft, Aortic Aneurysm Treatment (MIH, Class III) · First FDA decision May 9, 2001, newest Sep 13, 2011Aortic aneurysm and dissection
Last checked: Nov 19, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
11
PMA pathway
Device trials
3
Naming "Aneurx"
MAUDE reports
958
Brand "Aneurx", since 2015
PubMed studies
245
Mentioning "Aneurx"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Aneurx Stent Graft System
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 5 of 11 decisions filed under this name.
- ANEURX STENT GRAFT SYSTEMPMA supplement
P990020-S034 · Decided Sep 13, 2011 · 921 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
- ANEURX STENT GRAFT SYSTEMPMA supplement
P990020-S032 · Decided Sep 11, 2008 · 164 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
- ANEURX STENT GRAFT WITH XCELERANT DELIVERY SYSTEMPMA supplement
P990020-S017 · Decided Oct 28, 2004 · 85 days after receipt · Normal 180 Day Track
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
2 more FDA decisions with a free account
Older decisions: P990020-S011, P990020-S010, P990020-S009, P990020-S007, P990020-S006
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
- Application of Skin Substitute Grafts for Treatment of DFU and VLU of Lower ExtremitiesLocal determinationIn effectL36377First Coast Service Options, Inc.Updated Nov 21, 2019
Clinical trials
Device studies on ClinicalTrials.gov that name "Aneurx", any status and sponsor, newest update first.
- Talent Aortic Cuff Stent Graft System Compassionate Use RegistryNo longer available
Medtronic CardiovascularPublic (MDT)
NCT00604643
Device: TALENT Aortic Cuff Abdominal Stent Graft · For: Abdominal Aortic Aneurysms
Sites: Montgomery, Alabama; Oakland, California; San Jose, California · 50 sites in all
Medtronic CardiovascularPublic (MDT)
NCT00604552 · 349 participants · Start Jul 2003 · Primary completion Feb 2008
Device: AneuRx Stent Graft · For: Abdominal Aneurysm
Sites: Tucson, Arizona; Royal Oak, Michigan; Morristown, New Jersey · 8 sites in all
- The (PIVOTAL) StudyPivotal-lookingTerminated
Medtronic CardiovascularPublic (MDT)
NCT00444821 · 728 participants · Start Mar 2005 · Primary completion Jan 2010
Device: AneuRx AAA stent graft / Talent AAA stent graft · For: ABDOMINAL AORTIC ANEURYSMS
Sites: Birmingham, Alabama; Tucson, Arizona; Little Rock, Arkansas · 65 sites in all
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Aneurx", and for the whole product code for context.
This brand
958 reports: 179 malfunction, 724 injury, 55 death
Whole product code MIH
43,674 reports: 7,807 malfunction, 32,331 injury, 3,518 death
Newest reports for this brand
- UNK-CV-SR- ANEURXMalfunction
9612164-2026-04311 · Received Aug 26, 2026 · Event dated Apr 14, 2026
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Leak/Splash; Migration or Expulsion of Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- UNK-CV-SR- ANEURXInjury
9612164-2026-04316 · Received Aug 26, 2026 · Event dated Apr 14, 2026
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Adverse Event Without Identified Device or Use Problem
Patient problem as coded: Unspecified Infection; Obstruction/Occlusion; Insufficient Information
- ANEURXMalfunction
9612164-2026-03849 · Received Jul 30, 2026 · Event dated Oct 15, 2025
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Leak/Splash; Migration or Expulsion of Device
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-1918-2008 · Started Apr 29, 2008 · Posted by FDA Sep 16, 2008
Reason given: Products may contain elevated endotoxin (pyrogen) levels above the firm's specifications, and the product is labeled as containing no pyrogen.
Cause as FDA categorized it: Material/Component Contamination
Z-0689-2008 · Started Dec 10, 2007 · Posted by FDA Apr 8, 2008
Reason given: Sterility compromised: Device sterility may be compromised as evidenced by a loss of outer package integrity.
Cause as FDA categorized it: Package design/selection · Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Published research
The most relevant PubMed records for "Aneurx"[tiab]. The summary above synthesizes these.
- The AneuRx stent graft: four-year results and worldwide experience 2000.
Zarins CK, White RA, Moll FL, et al. · J Vasc Surg · 2001Review
- Outcomes after Partial Endograft Explantation.
Steenberge SP, Lyden SP, Turney EJ, et al. · Ann Vasc Surg · 2016
- AneuRx device migration: incidence, risk factors, and consequences.
Sampaio SM, Panneton JM, Mozes G, et al. · Ann Vasc Surg · 2005Research Support, Non-U.S. Gov't
- The US AneuRx Clinical Trial: 6-year clinical update 2002.
Zarins CK · J Vasc Surg · 2003Clinical Trial, Multicenter Study
- A comparison of AneuRx aortic cuff and zenith distal flare exclusion of common iliac artery ectasia for endovascular aneurysm repair.
Hakaim AG, Lau LL, Neuhauser B, et al. · Vasc Endovascular Surg · 2004Clinical Trial, Comparative Study
- The AneuRx modular endograft device for the treatment of abdominal aortic aneurysms. Overview of 7 years of clinical use.
Schmittling ZC, McLafferty RB, Danetz JS, et al. · J Cardiovasc Surg (Torino) · 2004Review
- Indications and outcomes of AneuRx Phase III trial versus use of commercial AneuRx stent graft.
Ayerdi J, McLafferty RB, Markwell SJ, et al. · J Vasc Surg · 2003Comparative Study, Research Support, Non-U.S. Gov't
- Intraaortic stabilization of the AneuRx stent-graft system: a useful adjunct to minimize device migration.
Lin PH, Martin L, Matsuura JH, et al. · Cardiovasc Intervent Radiol · 2003
- Strategies and outcomes for aortic endograft explantation.
Arnaoutakis DJ, Sharma G, Blackwood S, et al. · J Vasc Surg · 2019
- AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: multicenter prospective clinical trial.
Zarins CK, White RA, Schwarten D, et al. · J Vasc Surg · 1999Clinical Trial, Clinical Trial, Phase I
- Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome.
Zarins CK, Arko FR, Crabtree T, et al. · J Vasc Surg · 2004
- Stent graft migration after endovascular aneurysm repair: importance of proximal fixation.
Zarins CK, Bloch DA, Crabtree T, et al. · J Vasc Surg · 2003Clinical Trial, Clinical Trial, Phase I
Other devices of this type
Also filed under product code MIH.
- GORE® TAG® Thoracic Branch Endoprosthesis Zone 0/1W. L. Gore & Associates, Inc. · PMA 2026
- Ancure Endograft SystemBoston Scientific Corp · PMA 2003
- Talent Thoracic Stent Graft SystemMedtronic Vascular · PMA 2016
- GORE EXCLUDER AAA Endoprosthesis product familyW. L. Gore & Associates, Inc. · PMA 2021
- Talent Abdominal Stent Graft SystemMedtronic Vascular · PMA 2014
- TREO® Abdominal Stent-Graft SystemBolton Medical, Inc. · PMA 2026
- Zenith Fenestrated AAA Endovascular GraftCook, Inc. · PMA 2022
- Powerlink System with Intuitrak Delivery SystemEndologix, LLC · PMA 2013
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.