PMA device
Zenith Fenestrated AAA Endovascular Graft
Cook, Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment (MIH, Class III) · First FDA decision Apr 4, 2012, newest Jan 20, 2022Aortic aneurysm and dissection
Last checked: Nov 19, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
7
PMA pathway
Device trials
18
Naming "Zenith Fenestrated AAA"
MAUDE reports
400
Brand "Zenith Fenestrated AAA", since 2015
PubMed studies
9
Mentioning "Zenith Fenestrated AAA"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Zenith Fenestrated AAA Endovascular Graft
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 6 of 7 decisions filed under this name.
- Zenith Fenestrated AAA Endovascular GraftPMA supplement
P020018-S060 · Decided Jan 20, 2022 · 181 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
- ZENITH FENESTRATED AAA ENDOVASCULAR GRAFTPMA supplement
P020018-S050 · Decided Apr 2, 2014 · 50 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
- ZENITH FENESTRATED AAA ENDOVASCULAR GRAFTPMA supplement
P020018-S048 · Decided May 9, 2013 · 52 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
3 more FDA decisions with a free account
Older decisions: P020018-S040
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
- Application of Skin Substitute Grafts for Treatment of DFU and VLU of Lower ExtremitiesLocal determinationIn effectL36377First Coast Service Options, Inc.Updated Nov 21, 2019
Clinical trials
Device studies on ClinicalTrials.gov that name "Zenith Fenestrated AAA", any status and sponsor, newest update first.
Gustavo S OderichAcademic, hospital or other
NCT02089607 · 760 participants (planned) · Start Mar 2014 · Primary completion Mar 2028
Device: CAAA and TAAA Arm; Aortic Arch Aneurysm Arm · For: Complex Abdominal Aortic Aneurysm; Thoracoabdominal Aortic Aneurysm; Aortic Arch Aneurysm and 1 more
Sites: Rochester, Minnesota; Houston, Texas · 3 sites in all
Yale UniversityAcademic, hospital or other
NCT02989948 · 80 participants (planned) · Start Apr 22, 2020 · Primary completion Dec 31, 2027
Device: Physician-modified aortic endograft · For: Aortic Aneurysm, Thoracoabdominal
Sites: New Haven, Connecticut; Lebanon, New Hampshire
Medstar Health Research InstituteAcademic, hospital or other
NCT04526938 · 200 participants (planned) · Start Sep 20, 2021 · Primary completion Sep 2028
Device: Physician-Modified Cook Zenith Alpha Thoracic Endovascular Graft · For: Juxtarenal Aortic Aneurysm; Suprarenal Aortic Aneurysm; Thoracoabdominal Aortic Aneurysm
Sites: Washington D.C., District of Columbia
15 more trials with a free account
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Zenith Fenestrated AAA", and for the whole product code for context.
This brand
400 reports: 62 malfunction, 271 injury, 62 death
Whole product code MIH
43,674 reports: 7,807 malfunction, 32,331 injury, 3,518 death
Newest reports for this brand
William A. Cook Australia, PTY LTD
9680654-2026-00112 · Received Oct 12, 2026 · Event dated Oct 2, 2026
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Material Twisted/Bent
Patient problem as coded: Insufficient Information
William A. Cook Australia, PTY LTD
3005580113-2026-00055 · Received Sep 30, 2026 · Event dated Aug 9, 2026
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Device Endoleak
Patient problem as coded: Clinical Endoleak
William A. Cook Australia, PTY LTD
3005580113-2026-00053 · Received Sep 24, 2026
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Device Endoleak
Patient problem as coded: Clinical Endoleak
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-3130-2011 · Started Apr 15, 2011 · Posted by FDA Sep 6, 2011
Reason given: The firm initiated this action in response to information that there may be potential damage in the braided suture which is used to attach the external stents to the graft material.
Cause as FDA categorized it: Process control · Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Z-3131-2011 · Started Apr 15, 2011 · Posted by FDA Sep 6, 2011
Reason given: The firm initiated this action in response to information that there may be potential damage in the braided suture which is used to attach the external stents to the graft material.
Cause as FDA categorized it: Process control · Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Z-3132-2011 · Started Apr 15, 2011 · Posted by FDA Sep 6, 2011
Reason given: The firm initiated this action in response to information that there may be potential damage in the braided suture which is used to attach the external stents to the graft material.
Cause as FDA categorized it: Process control · Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
108 more recall records with a free account
Published research
The most relevant PubMed records for "Zenith Fenestrated AAA"[tiab]. The summary above synthesizes these.
- Anatomical feasibility of fenestrated stent graft to treat complex abdominal aortic aneurysms from a Korean single institute database.
Hyun S, Kim H, Mok SK, et al. · Ann Surg Treat Res · 2023
- Migration of fenestrated aortic stent grafts.
England A, García-Fiñana M, Fisher RK, et al. · J Vasc Surg · 2013Research Support, Non-U.S. Gov't
- Balloon guidance for superior mesenteric artery scallop alignment during Cook Zenith Fenestrated AAA Endovascular Graft deployment.
Kuwayama DP, Zacharias N · J Vasc Surg Cases Innov Tech · 2020
- Superior mesenteric artery outcomes after large fenestration strut relocation with the Zenith Fenestrated endoprosthesis.
Mirza AK, Sullivan TM, Skeik N, et al. · CVIR Endovasc · 2020
- Final 5-year results of the United States Zenith Fenestrated prospective multicenter study for juxtarenal abdominal aortic aneurysms.
Oderich GS, Farber MA, Schneider D, et al. · J Vasc Surg · 2021Clinical Study, Multicenter Study
- Gender and perioperative outcomes after fenestrated endovascular repair using custom-made and off-the-shelf devices.
Timaran DE, Knowles M, Soto-Gonzalez M, et al. · J Vasc Surg · 2016Comparative Study, Observational Study
- Select type I and type III endoleaks at the completion of fenestrated endovascular aneurysm repair resolve spontaneously.
Swerdlow NJ, McCallum JC, Liang P, et al. · J Vasc Surg · 2019Comparative Study, Research Support, N.I.H., Extramural
- Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms.
Oderich GS, Greenberg RK, Farber M, et al. · J Vasc Surg · 2014Clinical Trial, Multicenter Study
- Intermediate results of a United States multicenter trial of fenestrated endograft repair for juxtarenal abdominal aortic aneurysms.
Greenberg RK, Sternbergh WC, Makaroun M, et al. · J Vasc Surg · 2009Clinical Trial, Multicenter Study
Other devices of this type
Also filed under product code MIH.
- GORE® TAG® Thoracic Branch Endoprosthesis Zone 0/1W. L. Gore & Associates, Inc. · PMA 2026
- Ancure Endograft SystemBoston Scientific Corp · PMA 2003
- Aneurx Stent Graft SystemMedtronic Vascular · PMA 2011
- Talent Thoracic Stent Graft SystemMedtronic Vascular · PMA 2016
- GORE EXCLUDER AAA Endoprosthesis product familyW. L. Gore & Associates, Inc. · PMA 2021
- Talent Abdominal Stent Graft SystemMedtronic Vascular · PMA 2014
- TREO® Abdominal Stent-Graft SystemBolton Medical, Inc. · PMA 2026
- Powerlink System with Intuitrak Delivery SystemEndologix, LLC · PMA 2013
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.