PMA device
Talent Thoracic Stent Graft System
Medtronic Vascular · System, Endovascular Graft, Aortic Aneurysm Treatment (MIH, Class III) · First FDA decision Jun 27, 2008, newest Apr 5, 2016Aortic aneurysm and dissection
Last checked: Nov 20, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
10
PMA pathway
Device trials
6
Naming "Talent Thoracic"
MAUDE reports
70
Brand "Talent Thoracic", since 2015
PubMed studies
32
Mentioning "Talent Thoracic"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Talent Thoracic Stent Graft System
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 6 of 10 decisions filed under this name.
- TALENT THORACIC STENT GRAFT SYSTEMPMA supplement
P070007-S038 · Decided Apr 5, 2016 · 445 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
- TALENT THORACIC STENT GRAFT SYSTEMPMA supplement
P070007-S024 · Decided Jan 4, 2011 · 60 days after receipt · Normal 180 Day Track No User Fee
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
- TALENT THORACIC STENT GRAFT SYSTEMPMA supplement
P070007-S021 · Decided Oct 26, 2010 · 57 days after receipt · Normal 180 Day Track
Device type: SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT (MIH) · Cardiology
3 more FDA decisions with a free account
Older decisions: P070007-S005, P070007-S004, P070007-S002, P070007-S001
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
- Application of Skin Substitute Grafts for Treatment of DFU and VLU of Lower ExtremitiesLocal determinationIn effectL36377First Coast Service Options, Inc.Updated Nov 21, 2019
Clinical trials
Device studies on ClinicalTrials.gov that name "Talent Thoracic", any status and sponsor, newest update first.
Rodney A. White, M.D.Academic, hospital or other
NCT00597870 · 304 participants · Start May 2002 · Primary completion Jan 2021
Device: Endoluminal treament of thoracic lesions · For: Thoracic Aortic Aneurysms; Thoracic Transections; Intramural Hematoma and 2 more
Sites: Torrance, California
Medtronic CardiovascularPublic (MDT)
NCT00604799 · 379 participants · Start Jul 2003 · Primary completion Jun 2006
Device: Talent Thoracic Stent Graft · For: Thoracic Aortic Aneurysms
Sites: Philadelphia, Pennsylvania
Medtronic CardiovascularPublic (MDT)
NCT00805948 · 349 participants · Start Apr 2009 · Primary completion Aug 2016
Device: Talent Thoracic Stent Graft System · For: Thoracic Aortic Aneurysms
Sites: Los Angeles, California; Torrance, California; Washington D.C., District of Columbia · 26 sites in all
3 more trials with a free account
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Talent Thoracic", and for the whole product code for context.
This brand
70 reports: 8 malfunction, 48 injury, 14 death
Whole product code MIH
43,674 reports: 7,807 malfunction, 32,331 injury, 3,518 death
Newest reports for this brand
MEDTRONIC CARDIOVASCULAR SANTA ROSA
2953200-2024-00004 · Received May 15, 2024 · Event dated May 9, 2022
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Fracture; Adverse Event Without Identified Device or Use Problem
Patient problem as coded: Insufficient Information
9612164-2022-02499 · Received Jul 4, 2022
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Leak/Splash
Patient problem as coded: Insufficient Information; No Clinical Signs, Symptoms or Conditions
9612164-2022-01838 · Received May 16, 2022 · Event dated May 13, 2022
Device type: System, Endovascular Graft, Aortic Aneurysm Treatment (MIH)
Device problem as coded: Fracture; Leak/Splash
Patient problem as coded: Insufficient Information
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
No recall in FDA's data is linked to these FDA numbers.
Published research
The most relevant PubMed records for "Talent Thoracic"[tiab]. The summary above synthesizes these.
- Experience with early TEVAR treatment of uncomplicated type B aortic dissection.
Lin J, Marrocco C, Galovich J, et al. · J Cardiovasc Surg (Torino) · 2013Review
- Update on thoracic aortic endovascular grafting using the medtronic talent device.
Kwolek CJ, Fairman R · Semin Vasc Surg · 2006Review
- Short-term conversion to open surgery after endovascular stent-grafting of the thoracic aorta: the Talent thoracic registry.
Ehrlich MP, Nienaber CA, Rousseau H, et al. · J Thorac Cardiovasc Surg · 2008
- Endovascular repair of traumatic aortic injuries.
Neschis DG, Scalea TM · Adv Surg · 2010Review
- Blunt traumatic aortic injury: initial experience with endovascular repair.
Azizzadeh A, Keyhani K, Miller CC, et al. · J Vasc Surg · 2009
- Results with the Talent thoracic stent graft in the VALOR trial.
Foley PJ, Criado FJ, Farber MA, et al. · J Vasc Surg · 2012Clinical Trial, Multicenter Study
- Scallop technique of urgent endovascular repair for symptomatic throacoabdominal aortic aneurysm with a ready-made device.
Kawamura M, Kuratani T, Shirakawa Y, et al. · Ann Vasc Surg · 2013Case Reports
- Early outcome of endovascular treatment of acute traumatic aortic injuries: the talent thoracic retrospective registry.
Ehrlich MP, Rousseau H, Heijman R, et al. · Ann Thorac Surg · 2009Comparative Study, Multicenter Study
- Stent strut penetration during thoracic endovascular aortic repair: report of a case.
Tadakoshi M, Ishibashi H, Ishiguchi T, et al. · Surg Today · 2012Case Reports
- Propensity-matched cohort validates findings of the VALOR trial.
Patel VI, Conrad MF, Kwolek CJ, et al. · J Vasc Surg · 2011Clinical Trial, Comparative Study
- Emergency treatment of the thoracic aorta: results in 113 consecutive acute patients (the Talent Thoracic Retrospective Registry).
Kaya A, Heijmen RH, Rousseau H, et al. · Eur J Cardiothorac Surg · 2009Evaluation Study, Multicenter Study
- Case report and review of the literature total endovascular repair of acute ascending aortic rupture: a case report and review of the literature.
McCallum JC, Limmer KK, Perricone A, et al. · Vasc Endovascular Surg · 2013Case Reports, Review
Other devices of this type
Also filed under product code MIH.
- GORE® TAG® Thoracic Branch Endoprosthesis Zone 0/1W. L. Gore & Associates, Inc. · PMA 2026
- Ancure Endograft SystemBoston Scientific Corp · PMA 2003
- Aneurx Stent Graft SystemMedtronic Vascular · PMA 2011
- GORE EXCLUDER AAA Endoprosthesis product familyW. L. Gore & Associates, Inc. · PMA 2021
- Talent Abdominal Stent Graft SystemMedtronic Vascular · PMA 2014
- TREO® Abdominal Stent-Graft SystemBolton Medical, Inc. · PMA 2026
- Zenith Fenestrated AAA Endovascular GraftCook, Inc. · PMA 2022
- Powerlink System with Intuitrak Delivery SystemEndologix, LLC · PMA 2013
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.