Device type · PNW
Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant
Last checked: Nov 20, 2026Source: openFDAMethods & limitations
Product code
PNW
Orthopedic
Device class
Class III
FDA decisions since 2015
1
510(k), De Novo and PMA
Adverse event reports
57
Received Nov 1, 2025 to Nov 20, 2026
How FDA classifies it
- Device type
- Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant
- Product code
- PNW
- Device class
- Class III
- Review panel
- Orthopedic
- Specialty
- Orthopedic Surgery, Joint Reconstruction
- FDA record
- Classification database entry for PNW
Latest FDA decisions
P150017 · Decided Jul 1, 2016 · 427 days after receipt
Device type: Prosthesis, metatarsophalangeal joint cartilage replacement implant (PNW) · Orthopedic Surgery
Reports received
57
Received Nov 1, 2025 to Nov 20, 2026
Malfunction reports
0
0.0% of reports
Injury reports
57
100% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 0 | 1 | 0 | 0 |
| Jan 24 | 0 | 1 | 0 | 0 |
| Feb 24 | 0 | 0 | 0 | 0 |
| Mar 24 | 0 | 0 | 0 | 0 |
| Apr 24 | 0 | 0 | 0 | 0 |
| May 24 | 0 | 2 | 0 | 0 |
| Jun 24 | 0 | 0 | 0 | 0 |
| Jul 24 | 0 | 0 | 0 | 0 |
| Aug 24 | 0 | 0 | 0 | 0 |
| Sep 24 | 0 | 0 | 0 | 0 |
| Oct 24 | 0 | 1 | 0 | 0 |
| Nov 24 | 0 | 1 | 0 | 0 |
| Dec 24 | 0 | 36 | 0 | 0 |
| Jan 25 | 0 | 143 | 0 | 0 |
| Feb 25 | 0 | 3 | 0 | 0 |
| Mar 25 | 0 | 9 | 0 | 0 |
| Apr 25 | 0 | 1 | 0 | 0 |
| May 25 | 0 | 11 | 0 | 0 |
| Jun 25 | 0 | 34 | 0 | 0 |
| Jul 25 | 0 | 4 | 0 | 0 |
| Aug 25 | 0 | 28 | 0 | 0 |
| Sep 25 | 0 | 0 | 0 | 0 |
| Oct 25 | 0 | 21 | 0 | 0 |
| Nov 25 | 0 | 0 | 0 | 0 |
| Dec 25 | 0 | 3 | 0 | 0 |
| Jan 26 | 0 | 3 | 0 | 0 |
| Feb 26 | 0 | 5 | 0 | 0 |
| Mar 26 | 0 | 1 | 0 | 0 |
| Apr 26 | 0 | 0 | 0 | 0 |
| May 26 | 0 | 1 | 0 | 0 |
| Jun 26 | 0 | 4 | 0 | 0 |
| Jul 26 | 0 | 1 | 0 | 0 |
| Aug 26 | 0 | 28 | 0 | 0 |
| Sep 26 | 0 | 11 | 0 | 0 |
| Oct 26 | 0 | 0 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
- Cartiva56
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Adverse Event Without Identified Device or Use Problem48
- Implant subsidence2
- Insufficient Device Problem Information2
5 more in this ranking with a free account
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Pain35
- Insufficient Information16
- Arthritis6
7 more in this ranking with a free account
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- Cartiva Synthetic Cartilage Implant (SCI) Catalog: CAR-06-US (6mm), CAR-08-US (8mm), CAR-10-US (10mm), CAR-12-US (12mm)Open, Classified
Z-0598-2025 · Started Oct 31, 2024 · Posted by FDA Dec 4, 2024
Reason given: Patients implanted with synthetic cartilage implant, may experience a higher-than expected occurrence rate of the following hazards: revision, removal, implant subsidence, displacement, pain, nerve damage or fragmentation.
Cause as FDA categorized it: Device Design
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.