Device type · KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
KWS
Orthopedic
Device class
Class II
FDA decisions since 2015
63
510(k), De Novo and PMA
Adverse event reports
2,669
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
- Product code
- KWS
- Device class
- Class II
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3660
- Specialty
- Orthopedic Surgery, Joint Reconstruction
- FDA record
- Classification database entry for KWS
Latest FDA decisions
The 8 newest of 63 since 2015.
K263583 · Decided Oct 28, 2026 · 28 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
K260721 · Decided Jul 22, 2026 · 139 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
K254084 · Decided Apr 6, 2026 · 109 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
K252418 · Decided Nov 6, 2025 · 97 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
K252416 · Decided Oct 29, 2025 · 89 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
K241292 · Decided Jan 30, 2025 · 267 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
Stryker Corporation (Tornier, Inc.)
K241878 · Decided Dec 6, 2024 · 161 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
Stryker Corporation (Tornier, Inc.)
K241609 · Decided Sep 10, 2024 · 97 days after receipt
Device type: Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented (KWS) · Orthopedic Surgery
Reports received
2,669
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
184
6.9% of reports
Injury reports
2,485
93% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 16 | 127 | 0 | 0 |
| Jan 24 | 30 | 133 | 0 | 0 |
| Feb 24 | 30 | 140 | 0 | 0 |
| Mar 24 | 24 | 211 | 0 | 0 |
| Apr 24 | 20 | 188 | 0 | 0 |
| May 24 | 25 | 147 | 0 | 1 |
| Jun 24 | 28 | 174 | 0 | 0 |
| Jul 24 | 12 | 136 | 0 | 0 |
| Aug 24 | 9 | 191 | 0 | 0 |
| Sep 24 | 15 | 147 | 0 | 0 |
| Oct 24 | 10 | 131 | 0 | 0 |
| Nov 24 | 21 | 130 | 0 | 0 |
| Dec 24 | 22 | 147 | 0 | 0 |
| Jan 25 | 26 | 161 | 0 | 0 |
| Feb 25 | 23 | 184 | 0 | 0 |
| Mar 25 | 32 | 179 | 0 | 0 |
| Apr 25 | 18 | 177 | 0 | 0 |
| May 25 | 25 | 211 | 0 | 0 |
| Jun 25 | 14 | 161 | 0 | 0 |
| Jul 25 | 15 | 190 | 0 | 0 |
| Aug 25 | 22 | 154 | 0 | 0 |
| Sep 25 | 15 | 145 | 1 | 0 |
| Oct 25 | 19 | 182 | 0 | 0 |
| Nov 25 | 13 | 155 | 0 | 0 |
| Dec 25 | 12 | 181 | 0 | 0 |
| Jan 26 | 19 | 207 | 0 | 0 |
| Feb 26 | 20 | 203 | 0 | 0 |
| Mar 26 | 27 | 192 | 0 | 0 |
| Apr 26 | 21 | 336 | 0 | 0 |
| May 26 | 8 | 207 | 0 | 0 |
| Jun 26 | 15 | 159 | 0 | 0 |
| Jul 26 | 15 | 150 | 0 | 0 |
| Aug 26 | 15 | 186 | 0 | 0 |
| Sep 26 | 5 | 301 | 0 | 0 |
| Oct 26 | 14 | 208 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Adverse Event Without Identified Device or Use Problem1,033
- Device Dislodged or Dislocated303
- Unstable261
- Patient Device Interaction Problem244
- Fracture219
- Insufficient Device Problem Information205
- Loosening of Implant Not Related to Bone-Ingrowth135
- Loss of Osseointegration86
- Naturally Worn75
- Detachment of Device or Device Component72
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Insufficient Information455
- Unspecified Infection424
- Joint Laxity350
- Pain272
- Joint Dislocation254
- Bone Fracture(s)202
- No Clinical Signs, Symptoms or Conditions187
- Osteolysis126
- Post Operative Wound Infection99
- Failure of Implant97
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-3200-2026 · Started Jul 30, 2026 · Posted by FDA Sep 16, 2026
Reason given: Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or...
Cause as FDA categorized it: Process change control
Z-1769-2026 · Started Mar 5, 2026 · Posted by FDA Apr 3, 2026
Reason given: Affected products were incorrectly labeled as Tornier HRS Max products. These parts are compatible with the Tornier HRS system only, and are incompatible with the Tornier HRS Max system.
Cause as FDA categorized it: Labeling design
Z-1458-2026 · Started Jan 15, 2026 · Posted by FDA Feb 24, 2026
Reason given: Knee and Humeral socket implants contain incorrect labeling.
Cause as FDA categorized it: Process control
Z-1237-2026 · Started Dec 19, 2025 · Posted by FDA Feb 2, 2026
Reason given: A specific lot of screws is incorrectly labeled. Screws are labeled as 5.0mmx18mm but actual screws are 5.00mmx14mm. If mismatch is detected during surgery, the issue may cause a minor delay in surgery. If not detected and incorrect screw is used, issue may increase risk of earlier mechanical failure, loosening, and...
Cause as FDA categorized it: Labeling mix-ups
Z-2546-2025 · Started Jul 18, 2025 · Posted by FDA Sep 10, 2025
Reason given: Their is a potential that the reamer may kick or bind up during or immediately prior to use.
Cause as FDA categorized it: Device Design
Z-2547-2025 · Started Jul 18, 2025 · Posted by FDA Sep 10, 2025
Reason given: Their is a potential that the reamer may kick or bind up during or immediately prior to use.
Cause as FDA categorized it: Device Design
Z-2548-2025 · Started Jul 18, 2025 · Posted by FDA Sep 10, 2025
Reason given: Their is a potential that the reamer may kick or bind up during or immediately prior to use.
Cause as FDA categorized it: Device Design
Z-1402-2024 · Started Mar 6, 2024 · Posted by FDA Mar 29, 2024
Reason given: The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).
Cause as FDA categorized it: Nonconforming Material/Component
Showing the 8 newest of 153 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.