Device type · FQO
Table, Operating-Room, Ac-Powered
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
FQO
General & Plastic Surgery
Device class
Class I
FDA decisions since 2015
2
510(k), De Novo and PMA
Adverse event reports
184
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Table, Operating-Room, Ac-Powered
- Product code
- FQO
- Device class
- Class I
- Review panel
- General & Plastic Surgery
- Regulation
- 21 CFR 878.4960
- Specialty
- General & Plastic Surgery
- FDA record
- Classification database entry for FQO
Latest FDA decisions
- Maestro System (REF100)510(k)
K240598 · Decided Jun 3, 2024 · 91 days after receipt
Device type: Table, Operating-Room, Ac-Powered (FQO) · General & Plastic Surgery
- Maestro Platform510(k)
K221410 · Decided Dec 2, 2022 · 200 days after receipt
Device type: Table, Operating-Room, Ac-Powered (FQO) · General & Plastic Surgery
Reports received
184
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
99
54% of reports
Injury reports
84
46% of reports
Death reports
1
0.5% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 23 | 0 | 0 | 0 |
| Jan 24 | 15 | 0 | 0 | 0 |
| Feb 24 | 12 | 3 | 0 | 0 |
| Mar 24 | 12 | 0 | 0 | 0 |
| Apr 24 | 14 | 0 | 0 | 0 |
| May 24 | 14 | 2 | 0 | 0 |
| Jun 24 | 9 | 0 | 0 | 0 |
| Jul 24 | 8 | 2 | 0 | 0 |
| Aug 24 | 10 | 2 | 0 | 0 |
| Sep 24 | 4 | 0 | 0 | 0 |
| Oct 24 | 7 | 2 | 0 | 0 |
| Nov 24 | 8 | 1 | 0 | 0 |
| Dec 24 | 10 | 4 | 0 | 0 |
| Jan 25 | 7 | 0 | 0 | 0 |
| Feb 25 | 13 | 2 | 0 | 0 |
| Mar 25 | 4 | 0 | 0 | 0 |
| Apr 25 | 11 | 0 | 0 | 0 |
| May 25 | 15 | 4 | 0 | 0 |
| Jun 25 | 6 | 2 | 0 | 0 |
| Jul 25 | 6 | 0 | 0 | 0 |
| Aug 25 | 9 | 0 | 0 | 0 |
| Sep 25 | 7 | 2 | 0 | 0 |
| Oct 25 | 5 | 0 | 0 | 0 |
| Nov 25 | 9 | 3 | 0 | 0 |
| Dec 25 | 8 | 2 | 0 | 0 |
| Jan 26 | 11 | 2 | 1 | 0 |
| Feb 26 | 10 | 2 | 0 | 0 |
| Mar 26 | 6 | 41 | 0 | 0 |
| Apr 26 | 12 | 0 | 0 | 0 |
| May 26 | 7 | 6 | 0 | 0 |
| Jun 26 | 3 | 4 | 0 | 0 |
| Jul 26 | 7 | 3 | 0 | 0 |
| Aug 26 | 7 | 3 | 0 | 0 |
| Sep 26 | 15 | 8 | 0 | 0 |
| Oct 26 | 4 | 10 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
7 more in this ranking with a free account
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Insufficient Device Problem Information43
- Adverse Event Without Identified Device or Use Problem41
- Unintended Movement40
7 more in this ranking with a free account
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions100
- Pressure Sore/Ulcer40
- Crushing Injury8
7 more in this ranking with a free account
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-3033-2026 · Started Aug 6, 2026 · Posted by FDA Aug 26, 2026
Reason given: The linear actuator and rotational lock mechanism components may experience a mechanical failure that prevents the system from transitioning between locked and unlocked state. This may pose a risk of injury to the patient if unintended rotational movement occurs during a procedure.
Cause as FDA categorized it: Nonconforming Material/Component
- Corin Operating Tables Model Numbers: (1) 770001A0, (2) 770001A2, (3) 770001B0, (4) 770001B2, (5) 770001F0, (6) 770001F2; All Software Versions.Open, Classified
Z-2420-2025 · Started Jul 14, 2025 · Posted by FDA Aug 22, 2025
Reason given: Under certain conditions, such as the simultaneous use of the operating table with other medical devices, including high-frequency (HF) surgical equipment, interference may occur that could prevent the device from performing as intended. If the issue occurs, the operating table is unresponsive to command from both the...
Cause as FDA categorized it: Under Investigation by firm
- Skytron Freedom 4FXS-60 Heavy Duty Monitor MountOpen, Classified
Z-1663-2025 · Started Mar 27, 2025 · Posted by FDA Apr 23, 2025
Reason given: The mounting hardware that is supplied with the 4FXS-60 monitor bracket does not provide adequate thread engagement to support the weight of the frame and monitor. This could lead to a failure of the mounting hardware and subsequent separation of the frame from the mounting column.
Cause as FDA categorized it: Process change control
70 more recall records with a free account
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.