Device type · FKX
System, Peritoneal, Automatic Delivery
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
FKX
Gastroenterology & Urology
Device class
Class II
FDA decisions since 2015
11
510(k), De Novo and PMA
Adverse event reports
3,146
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- System, Peritoneal, Automatic Delivery
- Product code
- FKX
- Device class
- Class II
- Review panel
- Gastroenterology & Urology
- Regulation
- 21 CFR 876.5630
- Specialty
- GI, Urology & Nephrology, Gastroenterology, Nephrology
- FDA record
- Classification database entry for FKX
Latest FDA decisions
The 8 newest of 11 since 2015.
K250523 · Decided Oct 2, 2025 · 223 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
K243371 · Decided May 16, 2025 · 198 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
K220935 · Decided Dec 29, 2022 · 273 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
Fresenius Medical Care Renal Therapies Group, LLC
K222318 · Decided Oct 31, 2022 · 90 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
- Lilliput APD System510(k)
Fresenius Medical Care Renal Therapies Group, LLC
K212522 · Decided Apr 15, 2022 · 247 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
K212658 · Decided Feb 9, 2022 · 170 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
K201867 · Decided Nov 19, 2020 · 135 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
Fresenius Medical Care Renal Therapies Group, LLC
K181108 · Decided May 24, 2018 · 27 days after receipt
Device type: System, Peritoneal, Automatic Delivery (FKX) · GI, Urology & Nephrology
Reports received
3,146
Received Nov 1, 2025 to Nov 19, 2026. Includes 6 of another or unstated type.
Malfunction reports
1,692
54% of reports
Injury reports
1,369
44% of reports
Death reports
79
2.5% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 218 | 77 | 11 | 0 |
| Jan 24 | 266 | 91 | 3 | 0 |
| Feb 24 | 275 | 84 | 9 | 1 |
| Mar 24 | 207 | 72 | 5 | 0 |
| Apr 24 | 252 | 81 | 9 | 0 |
| May 24 | 213 | 92 | 7 | 0 |
| Jun 24 | 194 | 96 | 3 | 0 |
| Jul 24 | 234 | 134 | 4 | 0 |
| Aug 24 | 224 | 85 | 4 | 0 |
| Sep 24 | 230 | 78 | 4 | 0 |
| Oct 24 | 182 | 71 | 11 | 0 |
| Nov 24 | 164 | 59 | 6 | 0 |
| Dec 24 | 223 | 92 | 6 | 0 |
| Jan 25 | 174 | 81 | 7 | 0 |
| Feb 25 | 165 | 73 | 4 | 0 |
| Mar 25 | 164 | 69 | 8 | 0 |
| Apr 25 | 172 | 90 | 11 | 0 |
| May 25 | 154 | 101 | 6 | 0 |
| Jun 25 | 161 | 100 | 6 | 0 |
| Jul 25 | 147 | 91 | 7 | 0 |
| Aug 25 | 188 | 98 | 9 | 0 |
| Sep 25 | 148 | 92 | 8 | 0 |
| Oct 25 | 181 | 99 | 7 | 0 |
| Nov 25 | 181 | 104 | 2 | 0 |
| Dec 25 | 156 | 110 | 6 | 0 |
| Jan 26 | 129 | 90 | 11 | 0 |
| Feb 26 | 122 | 100 | 5 | 0 |
| Mar 26 | 146 | 80 | 6 | 0 |
| Apr 26 | 148 | 97 | 5 | 0 |
| May 26 | 136 | 120 | 8 | 0 |
| Jun 26 | 108 | 114 | 10 | 0 |
| Jul 26 | 128 | 149 | 5 | 1 |
| Aug 26 | 129 | 127 | 5 | 3 |
| Sep 26 | 127 | 142 | 6 | 1 |
| Oct 26 | 182 | 136 | 10 | 1 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Adverse Event Without Identified Device or Use Problem1,433
- Fluid/Blood Leak1,054
- Thermal Decomposition of Device183
- Protective Measures Problem157
- Disconnection99
- Overfill75
- Device Contamination with Chemical or Other Material53
- Loose or Intermittent Connection53
- Break33
- Air/Gas in Device29
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions1,610
- Peritonitis1,217
- Abdominal Pain664
- Peritoneal effluent abnormal365
- Increased Intra-Peritoneal Volume (IIPV)77
- Vomiting76
- Nausea67
- Dyspnea56
- Fever48
- Cardiac Arrest46
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-0409-2026 · Started Aug 28, 2025 · Posted by FDA Oct 29, 2025
Reason given: Vantive has identified a software defect within the Sharesource Claria software, which may cause a patient s updated prescription program settings to not be properly saved on the actual cycler that the patient is using to perform their therapy. As a result, the clinician may think that the patient is receiving the...
Cause as FDA categorized it: Software design
Z-0550-2024 · Started Nov 15, 2023 · Posted by FDA Dec 14, 2023
Reason given: There is to an increase in complaints related to failure alarms for Wet Cassette Integrity Test occurring on the Amia devices.
Cause as FDA categorized it: Process control
- Liberty Select Cycler, Model numbers RTLR180343 and RTLR180111Open, Classified
Fresenius Medical Care Holdings, Inc.
Z-0619-2024 · Started Oct 24, 2023 · Posted by FDA Dec 26, 2023
Reason given: Affected Liberty Select cyclers may display an incorrect time stamp on the treatment data report sent to the clinic.
Cause as FDA categorized it: Under Investigation by firm
- Automated Peritoneal Dialysis System. Used for automatic control of dialysis solution exchanges.Open, Classified
Z-1316-2023 · Started Feb 22, 2023 · Posted by FDA Apr 1, 2023
Reason given: The electrical safety testing was not properly performed on the impacted devices and additional testing is required
Cause as FDA categorized it: Process design
- Effluent Sample BagTerminated
Z-1144-2022 · Started Apr 21, 2022
Reason given: Certain Peritoneal Dialysis product codes do not have FDA regulatory clearance and were distributed within the United States in error.
Cause as FDA categorized it: No Marketing Application
Z-2173-2021 · Started Jun 30, 2021
Reason given: Baxter Healthcare Corporation has identified that the AMIA Sharesource User Guide that is used with the AMIA Automated PD System cyclers incorrectly describes the function of the UF (Ultrafiltration) Limit setting as the ending criteria of the cyclers Extra Last Drain Mode. In some locations in the guide, it states...
Cause as FDA categorized it: Under Investigation by firm
Z-2174-2021 · Started Jun 30, 2021
Reason given: Baxter Healthcare Corporation has identified that the AMIA Sharesource User Guide that is used with the AMIA Automated PD System cyclers incorrectly describes the function of the UF (Ultrafiltration) Limit setting as the ending criteria of the cyclers Extra Last Drain Mode. In some locations in the guide, it states...
Cause as FDA categorized it: Under Investigation by firm
Fresenius Medical Care Holdings, Inc.
Z-2085-2021 · Started Apr 28, 2021
Reason given: Exposed to freezing temperatures due to refrigerated truck malfunctions
Cause as FDA categorized it: Environmental control
Showing the 8 newest of 51 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.