Device type · FBN
Choledochoscope And Accessories, Flexible/Rigid
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
FBN
Gastroenterology & Urology
Device class
Class II
FDA decisions since 2015
17
510(k), De Novo and PMA
Adverse event reports
320
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Choledochoscope And Accessories, Flexible/Rigid
- Product code
- FBN
- Device class
- Class II
- Review panel
- Gastroenterology & Urology
- Regulation
- 21 CFR 876.1500
- Specialty
- GI, Urology & Nephrology
- FDA record
- Classification database entry for FBN
Latest FDA decisions
The 8 newest of 17 since 2015.
Mirco-Tech (Nanjing) Co., Ltd.
K254153 · Decided Apr 3, 2026 · 102 days after receipt
Device type: Choledochoscope And Accessories, Flexible/Rigid (FBN) · GI, Urology & Nephrology
- Disposable Distal Cap510(k)
Mirco-Tech (Nanjing) Co., Ltd.
K253139 · Decided Mar 19, 2026 · 175 days after receipt
Device type: Choledochoscope And Accessories, Flexible/Rigid (FBN) · GI, Urology & Nephrology
Scivita Medical Technology Co., Ltd.
K251338 · Decided Jan 20, 2026 · 265 days after receipt
Device type: Choledochoscope And Accessories, Flexible/Rigid (FBN) · GI, Urology & Nephrology
14 more FDA decisions with a free account
Reports received
320
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
290
91% of reports
Injury reports
26
8.1% of reports
Death reports
4
1.3% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 8 | 0 | 0 | 0 |
| Jan 24 | 6 | 0 | 0 | 0 |
| Feb 24 | 4 | 1 | 0 | 0 |
| Mar 24 | 9 | 0 | 0 | 0 |
| Apr 24 | 6 | 0 | 0 | 0 |
| May 24 | 13 | 0 | 1 | 0 |
| Jun 24 | 6 | 1 | 0 | 0 |
| Jul 24 | 13 | 1 | 1 | 0 |
| Aug 24 | 2 | 0 | 0 | 0 |
| Sep 24 | 7 | 0 | 0 | 0 |
| Oct 24 | 18 | 0 | 0 | 0 |
| Nov 24 | 8 | 2 | 1 | 0 |
| Dec 24 | 7 | 0 | 0 | 0 |
| Jan 25 | 4 | 0 | 0 | 0 |
| Feb 25 | 2 | 3 | 0 | 0 |
| Mar 25 | 7 | 0 | 0 | 0 |
| Apr 25 | 2 | 1 | 1 | 0 |
| May 25 | 7 | 0 | 0 | 0 |
| Jun 25 | 4 | 1 | 0 | 0 |
| Jul 25 | 12 | 0 | 0 | 0 |
| Aug 25 | 12 | 2 | 1 | 0 |
| Sep 25 | 17 | 0 | 0 | 0 |
| Oct 25 | 12 | 1 | 0 | 0 |
| Nov 25 | 9 | 0 | 0 | 0 |
| Dec 25 | 18 | 1 | 2 | 0 |
| Jan 26 | 11 | 0 | 0 | 0 |
| Feb 26 | 17 | 0 | 0 | 0 |
| Mar 26 | 38 | 0 | 0 | 0 |
| Apr 26 | 31 | 12 | 0 | 0 |
| May 26 | 15 | 10 | 0 | 0 |
| Jun 26 | 29 | 1 | 0 | 0 |
| Jul 26 | 27 | 0 | 0 | 0 |
| Aug 26 | 39 | 0 | 0 | 0 |
| Sep 26 | 38 | 2 | 1 | 0 |
| Oct 26 | 18 | 0 | 1 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
- Aizu Olympus161
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Optical Problem102
- Adverse Event Without Identified Device or Use Problem41
- Corroded37
7 more in this ranking with a free account
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions289
- Pancreatitis17
- Cholangitis12
7 more in this ranking with a free account
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- Tangent Endoscopy, Tangent Single Use Digital Catheter. Model Numbers: (1) TNG4002-IND. (2) TNG-4007-6pk.Open, Classified
Z-2209-2026 · Started Mar 23, 2026 · Posted by FDA May 15, 2026
Reason given: Affected devices exhibited fractures at the distal shaft tip without complete detachment.
Cause as FDA categorized it: Process control
Olympus Corporation of the Americas
Z-0905-2025 · Started Dec 18, 2024 · Posted by FDA Jan 16, 2025
Reason given: Potential for inadvertent retention of biomaterial when the reprocessing procedure is not performed as instructed, so as not completely removing and disassembling the device.
Cause as FDA categorized it: Labeling design
Z-0345-2024 · Started Sep 25, 2023 · Posted by FDA Nov 17, 2023
Reason given: Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection
Cause as FDA categorized it: Under Investigation by firm
6 more recall records with a free account
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.