Device type · CDQ
Urease And Glutamic Dehydrogenase, Urea Nitrogen
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
CDQ
Clinical Chemistry
Device class
Class II
FDA decisions since 2015
1
510(k), De Novo and PMA
Adverse event reports
11
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Urease And Glutamic Dehydrogenase, Urea Nitrogen
- Product code
- CDQ
- Device class
- Class II
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1770
- Specialty
- Laboratory Medicine & Pathology
- FDA record
- Classification database entry for CDQ
Latest FDA decisions
- Urea Nitrogen2510(k)
Abbott Ireland Diagnostics Division
K203771 · Decided May 31, 2022 · 524 days after receipt
Device type: Urease And Glutamic Dehydrogenase, Urea Nitrogen (CDQ) · Laboratory Medicine & Pathology
Reports received
11
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
11
100% of reports
Injury reports
0
0.0% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 0 | 0 | 0 | 0 |
| Jan 24 | 1 | 0 | 0 | 0 |
| Feb 24 | 0 | 0 | 0 | 0 |
| Mar 24 | 0 | 0 | 0 | 0 |
| Apr 24 | 0 | 0 | 0 | 0 |
| May 24 | 0 | 0 | 0 | 0 |
| Jun 24 | 0 | 0 | 0 | 0 |
| Jul 24 | 1 | 0 | 0 | 0 |
| Aug 24 | 0 | 0 | 0 | 0 |
| Sep 24 | 1 | 0 | 0 | 0 |
| Oct 24 | 0 | 0 | 0 | 0 |
| Nov 24 | 0 | 0 | 0 | 0 |
| Dec 24 | 1 | 0 | 0 | 0 |
| Jan 25 | 2 | 0 | 0 | 0 |
| Feb 25 | 0 | 0 | 0 | 0 |
| Mar 25 | 1 | 0 | 0 | 0 |
| Apr 25 | 1 | 0 | 0 | 0 |
| May 25 | 0 | 0 | 0 | 0 |
| Jun 25 | 0 | 0 | 0 | 0 |
| Jul 25 | 0 | 0 | 0 | 0 |
| Aug 25 | 1 | 0 | 0 | 0 |
| Sep 25 | 0 | 0 | 0 | 0 |
| Oct 25 | 1 | 0 | 0 | 0 |
| Nov 25 | 0 | 0 | 0 | 0 |
| Dec 25 | 0 | 0 | 0 | 0 |
| Jan 26 | 1 | 0 | 0 | 0 |
| Feb 26 | 0 | 0 | 0 | 0 |
| Mar 26 | 1 | 0 | 0 | 0 |
| Apr 26 | 2 | 0 | 0 | 0 |
| May 26 | 1 | 0 | 0 | 0 |
| Jun 26 | 0 | 0 | 0 | 0 |
| Jul 26 | 1 | 0 | 0 | 0 |
| Aug 26 | 2 | 0 | 0 | 0 |
| Sep 26 | 0 | 0 | 0 | 0 |
| Oct 26 | 3 | 0 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Low Test Results7
- Non Reproducible Results5
- High Test Results1
2 more in this ranking with a free account
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions11
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- ADVIA Chemistry Iron_2 (IRON_2) Reagents, Material Numbers 10377510 (6 x 350 tests) and 10341118 (7 x 145 tests)Open, Classified
Siemens Healthcare Diagnostics, Inc.
Z-2666-2023 · Started Aug 8, 2023 · Posted by FDA Sep 30, 2023
Reason given: There is a potential for a positive bias on Quality Control (QC) and patient sample results when using some IRON_2 reagent wedge pairs. When the issue occurs, the observed bias will vary wedge to wedge.
Cause as FDA categorized it: Under Investigation by firm
- Randox RX Series Urea Enzymatic Kinetic Assay Ref. Numbers: (1) UR3825 (2) UR3873 (3) UR8334 (4) UR8070 (Modena)Open, Classified
Z-2362-2023 · Started Jun 13, 2023 · Posted by FDA Aug 9, 2023
Reason given: Carryover from the Direct LDL-cholesterol assay on the Rx instruments may result in a negative bias, up to -11%, in quality control and patient samples, in urea assays results if the urea assay is run immediately after the Direct LDL-cholesterol assay. This may lead to a delay in reporting results or in falsely...
Cause as FDA categorized it: Under Investigation by firm
Siemens Healthcare Diagnostics, Inc.
Z-2062-2018 · Started Mar 27, 2018
Reason given: Urea Nitrogen reagent kit demonstrated an increased incidence of Calibration Failures. Results cannot be generated by the system when calibration fails.
Cause as FDA categorized it: Material/Component Contamination
3 more recall records with a free account
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.