Device type · BZE
Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
BZE
Anesthesiology
Device class
Class II
FDA decisions since 2015
15
510(k), De Novo and PMA
Adverse event reports
231
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer
- Product code
- BZE
- Device class
- Class II
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5270
- Specialty
- Anesthesiology & Respiratory, Pulmonology
- FDA record
- Classification database entry for BZE
Latest FDA decisions
The 8 newest of 15 since 2015.
Vincent Healthcare Products Limited
K252066 · Decided Jun 18, 2026 · 352 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
K253322 · Decided Mar 25, 2026 · 176 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
- Heated Breathing Tube510(k)
Guangdong Eda Technology Co., Ltd.
K243244 · Decided Jul 25, 2025 · 287 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
K241268 · Decided Aug 2, 2024 · 88 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
K234032 · Decided Jun 4, 2024 · 167 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
K222822 · Decided Jun 14, 2023 · 268 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
- Sunset Heated CPAP Tube510(k)
Sunset Healthcare Solutions, Inc.
K201418 · Decided Jan 29, 2021 · 245 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
K173280 · Decided Aug 2, 2018 · 290 days after receipt
Device type: Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer (BZE) · Anesthesiology & Respiratory
Reports received
231
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
230
100% of reports
Injury reports
1
0.4% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 14 | 0 | 0 | 0 |
| Jan 24 | 9 | 1 | 0 | 0 |
| Feb 24 | 13 | 0 | 0 | 0 |
| Mar 24 | 17 | 0 | 0 | 0 |
| Apr 24 | 7 | 0 | 0 | 0 |
| May 24 | 12 | 2 | 0 | 0 |
| Jun 24 | 14 | 0 | 0 | 0 |
| Jul 24 | 15 | 1 | 0 | 0 |
| Aug 24 | 16 | 0 | 0 | 0 |
| Sep 24 | 13 | 0 | 1 | 0 |
| Oct 24 | 6 | 1 | 0 | 0 |
| Nov 24 | 18 | 0 | 0 | 0 |
| Dec 24 | 26 | 0 | 0 | 0 |
| Jan 25 | 11 | 1 | 0 | 0 |
| Feb 25 | 18 | 1 | 0 | 0 |
| Mar 25 | 15 | 1 | 0 | 0 |
| Apr 25 | 12 | 0 | 0 | 0 |
| May 25 | 19 | 0 | 0 | 0 |
| Jun 25 | 19 | 0 | 0 | 0 |
| Jul 25 | 11 | 0 | 0 | 0 |
| Aug 25 | 13 | 0 | 0 | 0 |
| Sep 25 | 26 | 0 | 0 | 0 |
| Oct 25 | 12 | 0 | 0 | 0 |
| Nov 25 | 18 | 0 | 0 | 0 |
| Dec 25 | 18 | 0 | 0 | 0 |
| Jan 26 | 16 | 0 | 0 | 0 |
| Feb 26 | 17 | 0 | 0 | 0 |
| Mar 26 | 16 | 0 | 0 | 0 |
| Apr 26 | 21 | 0 | 0 | 0 |
| May 26 | 14 | 0 | 0 | 0 |
| Jun 26 | 15 | 1 | 0 | 0 |
| Jul 26 | 15 | 0 | 0 | 0 |
| Aug 26 | 32 | 0 | 0 | 0 |
| Sep 26 | 33 | 0 | 0 | 0 |
| Oct 26 | 15 | 0 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Gas/Air Leak70
- Crack67
- Fluid/Blood Leak63
- Leak/Splash29
- Insufficient Heating14
- Material Puncture/Hole14
- Loose or Intermittent Connection6
- Component Missing5
- Material Split, Cut or Torn5
- Damaged Thread4
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions227
- Hemodynamic instability1
- Hypoxia1
- Insufficient Information1
- Low Oxygen Saturation1
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-1697-2025 · Started Apr 10, 2025 · Posted by FDA May 9, 2025
Reason given: Adapters may disconnect during setup or while in use, potentially interrupting ventilation. Any disconnection can result in severe consequences for neonates, including hypoxia, hypercapnia, and organ failure.
Cause as FDA categorized it: Component design/selection
Z-1698-2025 · Started Apr 10, 2025 · Posted by FDA May 9, 2025
Reason given: Adapters may disconnect during setup or while in use, potentially interrupting ventilation. Any disconnection can result in severe consequences for neonates, including hypoxia, hypercapnia, and organ failure.
Cause as FDA categorized it: Component design/selection
Z-1912-2019 · Started May 10, 2019 · Posted by FDA Jul 15, 2019
Reason given: Reported complaints of cracks being observed, prior to use, on swivel wye adaptors of the Neonatal ConchaSmart Breathing Circuit.
Cause as FDA categorized it: Process control
Z-2689-2014 · Started Jul 31, 2014 · Posted by FDA Sep 23, 2014
Reason given: The CareFusion AirLife Heated Infant Breathing Circuit is being recalled due to a regulatory compliance risk involving a material change. The changes to the gas pathway may potentially impact the safety of the device and quality of the gas condensates to the patient.
Cause as FDA categorized it: No Marketing Application
Z-1899-2012 · Started May 29, 2012 · Posted by FDA Jun 29, 2012
Reason given: The Y adapter within the breathing circuit may spontaneously crack, causing a leak in the closed ventilation system. This leak could lead to a decrease in the tidal volume delivered to the ventilated patient.
Cause as FDA categorized it: Equipment maintenance
Z-1900-2012 · Started May 29, 2012 · Posted by FDA Jun 29, 2012
Reason given: The Y adapter within the breathing circuit may spontaneously crack, causing a leak in the closed ventilation system. This leak could lead to a decrease in the tidal volume delivered to the ventilated patient.
Cause as FDA categorized it: Equipment maintenance
Z-1901-2012 · Started May 29, 2012 · Posted by FDA Jun 29, 2012
Reason given: The Y adapter within the breathing circuit may spontaneously crack, causing a leak in the closed ventilation system. This leak could lead to a decrease in the tidal volume delivered to the ventilated patient.
Cause as FDA categorized it: Equipment maintenance
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.