Device type · BSZ
Gas-Machine, Anesthesia
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
BSZ
Anesthesiology
Device class
Class II
FDA decisions since 2015
17
510(k), De Novo and PMA
Adverse event reports
8,146
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Gas-Machine, Anesthesia
- Product code
- BSZ
- Device class
- Class II
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5160
- Specialty
- Anesthesiology & Respiratory
- FDA record
- Classification database entry for BSZ
Latest FDA decisions
The 8 newest of 17 since 2015.
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
K253330 · Decided Jun 25, 2026 · 268 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
K252746 · Decided May 21, 2026 · 265 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
K251352 · Decided Jul 11, 2025 · 72 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
- Atlan510(k)
K230931 · Decided Jul 23, 2023 · 111 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
- Carestation 750/750c510(k)
K213867 · Decided Mar 28, 2023 · 473 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
- A8, A9 Anesthesia System510(k)
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
K201957 · Decided Mar 26, 2021 · 255 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
K191027 · Decided Mar 18, 2020 · 335 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
- A5 Anesthesia System510(k)
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
K171311 · Decided Jan 12, 2018 · 255 days after receipt
Device type: Gas-Machine, Anesthesia (BSZ) · Anesthesiology & Respiratory
Reports received
8,146
Received Nov 1, 2025 to Nov 19, 2026. Includes 7 of another or unstated type.
Malfunction reports
8,059
99% of reports
Injury reports
74
0.9% of reports
Death reports
6
0.1% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 520 | 3 | 0 | 0 |
| Jan 24 | 475 | 2 | 2 | 0 |
| Feb 24 | 463 | 5 | 2 | 0 |
| Mar 24 | 476 | 0 | 1 | 0 |
| Apr 24 | 483 | 5 | 0 | 0 |
| May 24 | 496 | 1 | 0 | 0 |
| Jun 24 | 493 | 1 | 0 | 0 |
| Jul 24 | 553 | 1 | 0 | 0 |
| Aug 24 | 568 | 2 | 0 | 0 |
| Sep 24 | 479 | 2 | 0 | 0 |
| Oct 24 | 546 | 0 | 0 | 0 |
| Nov 24 | 494 | 2 | 0 | 0 |
| Dec 24 | 509 | 6 | 0 | 0 |
| Jan 25 | 432 | 3 | 0 | 0 |
| Feb 25 | 405 | 6 | 0 | 0 |
| Mar 25 | 539 | 8 | 1 | 0 |
| Apr 25 | 731 | 10 | 0 | 0 |
| May 25 | 1,224 | 7 | 0 | 0 |
| Jun 25 | 987 | 4 | 0 | 0 |
| Jul 25 | 1,082 | 2 | 1 | 0 |
| Aug 25 | 867 | 9 | 0 | 0 |
| Sep 25 | 706 | 10 | 0 | 0 |
| Oct 25 | 869 | 5 | 0 | 0 |
| Nov 25 | 653 | 6 | 0 | 0 |
| Dec 25 | 797 | 2 | 0 | 0 |
| Jan 26 | 552 | 9 | 0 | 0 |
| Feb 26 | 789 | 2 | 0 | 0 |
| Mar 26 | 743 | 26 | 1 | 0 |
| Apr 26 | 794 | 4 | 2 | 0 |
| May 26 | 707 | 6 | 1 | 0 |
| Jun 26 | 579 | 1 | 1 | 0 |
| Jul 26 | 682 | 4 | 1 | 0 |
| Aug 26 | 631 | 4 | 0 | 4 |
| Sep 26 | 605 | 7 | 0 | 2 |
| Oct 26 | 527 | 3 | 0 | 1 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
- Datex-Ohmeda4,999
- GE HealthCare2,716
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Flow1,524
- Therapeutic or Diagnostic Output Failure1,121
- Failure to Run on Battery946
- Insufficient Flow or Under Infusion849
- Mechanical Problem724
- Power Problem640
- Electrical /Electronic Property Problem612
- Unexpected Therapeutic Results274
- Failure to Power Up196
- Failure to Deliver180
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions8,060
- Hypoxia22
- Low Oxygen Saturation21
- Distress20
- Hypoventilation20
- Insufficient Information16
- Cardiac Arrest9
- Burn(s)7
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available2
- Red Eye(s)2
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- Aisys, Datex-Ohmeda anesthesia system, Part Number 1011-9050-000Open, Classified
Z-3189-2026 · Started Jul 30, 2026 · Posted by FDA Sep 16, 2026
Reason given: Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled or manual ventilation and initiates audible and visual alarms. When this issue...
Cause as FDA categorized it: Nonconforming Material/Component
Z-3190-2026 · Started Jul 30, 2026 · Posted by FDA Sep 16, 2026
Reason given: Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled or manual ventilation and initiates audible and visual alarms. When this issue...
Cause as FDA categorized it: Nonconforming Material/Component
- Aisys CS2 with Et Control, Datex-Ohmeda anesthesia system, Part Number 1011-9000-000Open, Classified
Z-3191-2026 · Started Jul 30, 2026 · Posted by FDA Sep 16, 2026
Reason given: Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled or manual ventilation and initiates audible and visual alarms. When this issue...
Cause as FDA categorized it: Nonconforming Material/Component
Z-3192-2026 · Started Jul 30, 2026 · Posted by FDA Sep 16, 2026
Reason given: Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled or manual ventilation and initiates audible and visual alarms. When this issue...
Cause as FDA categorized it: Nonconforming Material/Component
Z-2860-2026 · Started Jun 24, 2026 · Posted by FDA Aug 3, 2026
Reason given: Events observed where anesthetic agent was not delivered when the vaporizer was activated. Failure to deliver the anesthetic agent may result in the patient receiving insufficient anesthesia and may lead to intraoperative awareness.
Cause as FDA categorized it: Under Investigation by firm
- Atlan A350. Model Number: 8211500. anesthesia workstationOpen, Classified
Z-2207-2026 · Started May 7, 2026 · Posted by FDA Jun 4, 2026
Reason given: The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use or suffered a failure of the mechanical ventilation during use.
Cause as FDA categorized it: Process change control
- Atlan A350XL. Model Number: 8621600. anesthesia workstationOpen, Classified
Z-2208-2026 · Started May 7, 2026 · Posted by FDA Jun 4, 2026
Reason given: The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use or suffered a failure of the mechanical ventilation during use.
Cause as FDA categorized it: Process change control
GE Medical Systems China Co., Ltd.
Z-0913-2026 · Started Nov 14, 2025 · Posted by FDA Dec 18, 2025
Reason given: Potential unexpected shutdown of Carestation 600 and 700 Series Anesthesia Systems containing certain power management boards, if the AC mains power is unplugged or in the event of an AC mains power failure. Anesthesia systems only operate on battery power in a rare event that AC mains power is lost and there is no...
Cause as FDA categorized it: Component change control
Showing the 8 newest of 177 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.