PMA device
Precision Spinal Cord Stimulator (SCS) Systems
Boston Scientific Corp · Stimulator, Spinal-Cord, Totally Implanted For Pain Relief (LGW, Class III) · First FDA decision Apr 27, 2004, newest Jan 21, 2026Chronic pain
Last checked: Nov 20, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
40
PMA pathway
Device trials
487
Naming "Precision"
MAUDE reports
59,903
Brand "Precision", since 2015
PubMed studies
319,356
Mentioning "Precision"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Precision Spinal Cord Stimulator (SCS) Systems
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 6 of 40 decisions filed under this name.
- Precision Spinal Cord Stimulator (SCS) SystemsPMA supplement
P030017-S377 · Decided Jan 21, 2026 · 541 days after receipt · Normal 180 Day Track
Device type: Stimulator, spinal-cord, totally implanted for pain relief (LGW) · Neurology & Neurosurgery
- Precision, Precision Spectra, Precision Novi, Precision Montage, Precision Montage MRI, Spectra WaveWriter, WaveWriter APMA supplement
P030017-S357 · Decided Oct 5, 2023 · 281 days after receipt · Panel Track
Device type: Stimulator, spinal-cord, totally implanted for pain relief (LGW) · Neurology & Neurosurgery
- Precision, Precision Spectra, Precision Novi, Precision Montage, Precision Montage MRI and Spectra WaveWriter Spinal CorPMA supplement
P030017-S300 · Decided Jan 19, 2018 · 205 days after receipt · Normal 180 Day Track No User Fee
Device type: Stimulator, spinal-cord, totally implanted for pain relief (LGW) · Neurology & Neurosurgery
3 more FDA decisions with a free account
Older decisions: P030017-S279, P030017-S277, P030017-S270, P030017-S241, P030017-S210, P030017-S202, P030017-S191, P030017-S152, P030017-S134, P030017-S119, P030017-S102, P030017-S100, P030017-S095, P030017-S093, P030017-S091, P030017-S088, P030017-S071, P030017-S065, P030017-S053, P030017-S035, P030017-S033, P030017-S031, P030017-S030, P030017-S029, P030017-S023, P030017-S022, P030017-S020, P030017-S018, P030017-S017, P030017-S015, P030017-S014, P030017-S013, P030017-S008, P030017
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "Precision", any status and sponsor, newest update first.
- Neoadjuvant Concomitant Modulated Electro-hyperthermia in HER2-negative Breast CancerActive, not recruiting
Semmelweis UniversityAcademic, hospital or other
NCT05889390 · 71 participants · Start Feb 20, 2023 · Primary completion Oct 31, 2025
Device: Oncotherm EHY-2030 · For: HER2-negative Breast Cancer
Sites: Budapest, Hungary
Central South UniversityAcademic, hospital or other
NCT07640945 · 75 participants (planned) · Start Jun 20, 2026 · Primary completion Jan 2027
Device: continuous theta burst stimulation(cTBS) · For: Generalized Anxiety Disorder (GAD)
Sites: Changsha, China
- Precision Closed-loop Brain-Computer Interface Neuromodulation for Treatment-Resistant DepressionNot yet recruiting
Shanghai Mental Health CenterAcademic, hospital or other
NCT07783906 · 70 participants (planned) · Start Dec 2026 · Primary completion Dec 31, 2028
Device: Closed-loop Deep Brain Stimulation (DBS); Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) · For: Treatment-Resistant Major Depressive Disorder; Major Depressive Disorder
484 more trials with a free account
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Precision", and for the whole product code for context.
This brand
59,903 reports: 24,377 malfunction, 34,990 injury, 522 death
Whole product code LGW
301,867 reports: 79,174 malfunction, 220,939 injury, 1,642 death
Newest reports for this brand
- PRECISION IE 4K EYPC ASC ATCL4X30°140SLKMalfunction
0002936485-2026-01464 · Received Oct 30, 2026 · Event dated Oct 1, 2026
Device type: Arthroscope (HRX)
Device problem as coded: Poor Quality Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- PRECISION IE 4K EYPC ASC ATCL4X30°140SLKMalfunction
0002936485-2026-01465 · Received Oct 30, 2026 · Event dated Oct 2, 2026
Device type: Arthroscope (HRX)
Device problem as coded: Poor Quality Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- Precision? Montage? MRIInjury
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
3006630150-2026-08306 · Received Oct 30, 2026 · Event dated Oct 12, 2024
Device type: Stimulator, Spinal-Cord, Totally Implanted For Pain Relief (LGW)
Device problem as coded: Charging Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Boston Scientific Neuromodulation Corporation
Z-2879-2026 · Started Jun 17, 2026 · Posted by FDA Aug 5, 2026
Reason given: Spinal cord stimulation system lead body may be exposed to stress at the anchor site. This may result in high impedance measurements or lead fractures, which may lead to inadequate stimulation, additional intervention, including lead explant and replacement.
Cause as FDA categorized it: Device Design · Device type: Stimulator, Spinal-Cord, Totally Implanted For Pain Relief (LGW)
- Boston Scientific Model SC-4318, Clik X Anchor REF: M365SC43180Open, Classified
Boston Scientific Neuromodulation Corporation
Z-2404-2026 · Started Apr 29, 2026 · Posted by FDA Jun 11, 2026
Reason given: Sterile anchors my lack sterility assurance.
Cause as FDA categorized it: Packaging process control · Device type: Stimulator, Spinal-Cord, Totally Implanted For Pain Relief (LGW)
- WAVEWRITER ALPHA: Model: SC-1216, 16 IPG KIT, REF: M365SC12160; Model: SC-1232, 32 IPG KIT, REF: M365SC12320Open, Classified
Boston Scientific Neuromodulation Corporation
Z-2617-2024 · Started Jul 17, 2024 · Posted by FDA Aug 14, 2024
Reason given: Spinal Cord Stimulation (SCS) Implantable Pulse Generator (IPG) may experience routine system check during IPG charging, which may cause device reset, which may lead to transient loss of stimulation; patients may experience undesired sensations when therapy turns off for approx. 10-15 seconds and then back on, which...
Cause as FDA categorized it: Software design · Device type: Stimulator, Spinal-Cord, Totally Implanted For Pain Relief (LGW)
14 more recall records with a free account
Published research
The most relevant PubMed records for "Precision"[tiab]. The summary above synthesizes these.
- Precision surgery.
Boggi U · Updates Surg · 2023Editorial
- Precision Hypertension.
Dzau VJ, Hodgkinson CP · Hypertension · 2024Review
- Precision Oncology: 2025 in Review.
Mai N, Fernandez N, Drilon A, et al. · Cancer Discov · 2025Review
- Precision Medicine.
Van Eyk JE, Sobhani K · Circulation · 2018
- Precision medicine and therapies of the future.
Sisodiya SM · Epilepsia · 2021Research Support, Non-U.S. Gov't, Review
- Precision Psychiatry Applications with Pharmacogenomics: Artificial Intelligence and Machine Learning Approaches.
Lin E, Lin CH, Lane HY · Int J Mol Sci · 2020Review
- Precision interventional radiology.
Ji J, Fang S, Minjiang Chen, et al. · J Interv Med · 2021Editorial
- Precision of Echocardiographic Measurements.
Pillai B, Salerno M, Schnittger I, et al. · J Am Soc Echocardiogr · 2024Editorial
- "Precision" drug development?
Woodcock J · Clin Pharmacol Ther · 2016
- The Too-Much-Precision Effect.
Loschelder DD, Friese M, Schaerer M, et al. · Psychol Sci · 2016
- The ethics of precision health.
Delston JB · Bioethics · 2023
- Precision medicine in Thailand.
Shotelersuk V, Tongsima S, Pithukpakorn M, et al. · Am J Med Genet C Semin Med Genet · 2019Research Support, Non-U.S. Gov't, Review
Other devices of this type
Also filed under product code LGW.
- Senza Spinal Cord Stimulation (SCS) SystemNevro Corporation · PMA 2025
- Saluda Medical Evoke SCS SystemSaluda Medical Pty, Ltd. · PMA 2026
- Master RestoreMedtronic Neuromodulation · PMA 2026
- RestoreMedtronic Neuromodulation · PMA 2025
- Genesis and Eon Family Neurostimulation (Ipg) SystemsAbbott Medical · PMA 2016
- Genesis Neurostimulation SystemAbbott Medical · PMA 2024
- Precision Spectra Spinal Cord Stimulator (SCS) SystemBoston Scientific Corp · PMA 2021
- Proclaim family of SCS IPGsAbbott Medical · PMA 2021
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.