PMA device
Oxford Cementless Partial Knee System
Biomet Manufacturing Corp · Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing (NRA, Class III) · First FDA decision Nov 22, 2024, newest Nov 22, 2024Knee osteoarthritis
Last checked: Nov 20, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
1
PMA pathway
Device trials
3
Naming "Oxford Cementless Partial"
MAUDE reports
0
Brand "Oxford Cementless Partial", since 2015
PubMed studies
0
Mentioning "Oxford Cementless Partial"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Oxford Cementless Partial Knee System
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 1 of 1 decisions filed under this name.
- Oxford Cementless Partial Knee SystemPMA supplement
P010014-S105 · Decided Nov 22, 2024 · 536 days after receipt · Panel Track
Device type: Prosthesis, knee, femorotibial, unicompartmental, semi-constrained, metal/polymer, mobile bearing (NRA) · Orthopedic Surgery
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "Oxford Cementless Partial", any status and sponsor, newest update first.
- Safety and Efficacy of the Oxford Cementless Partial Knee SystemPivotal-lookingCompleted
Zimmer BiometPublic (ZBH)
NCT01473134 · 320 participants · Start Dec 2011 · Primary completion Nov 30, 2020
Device: Oxford Cementless Partial Knee; Oxford Cemented Partial Knee · For: Osteoarthritis, Knee; Avascular Necrosis of the Medial Femoral Condyle
Sites: Elkhart, Indiana; Indianapolis, Indiana; Council Bluffs, Iowa · 8 sites in all
University of AarhusAcademic, hospital or other
NCT00679120 · 75 participants (planned) · Start May 2009 · Primary completion Oct 2017
Device: Oxford Uni Knee; Oxford Uni Knee and 1 more · For: Osteoarthritis, Knee
Sites: Aarhus, Denmark
Zimmer BiometPublic (ZBH)
NCT00760188 · 0 participants · Start Dec 2011 · Primary completion Dec 2011
Device: Cementless Oxford Partial Knee · For: Arthroplasty, Replacement, Knee
Sites: Penrith, Australia
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Oxford Cementless Partial", and for the whole product code for context.
This brand
0 reports: 0 malfunction, 0 injury, 0 death
Whole product code NRA
4,438 reports: 183 malfunction, 4,196 injury, 58 death
Newest reports for this brand
No MAUDE reports name this brand.
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-1152-2017 · Started Jan 5, 2016
Reason given: Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product could lead to the cracking and separation of the instrument.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Orthopedic Manual Surgical Instrument (LXH)
Z-1153-2017 · Started Jan 5, 2016
Reason given: Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product could lead to the cracking and separation of the instrument.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Orthopedic Manual Surgical Instrument (LXH)
Z-1154-2017 · Started Jan 5, 2016
Reason given: Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product could lead to the cracking and separation of the instrument.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Driver, Prosthesis (HWR)
19 more recall records with a free account
Published research
The most relevant PubMed records for "Oxford Cementless Partial"[tiab]. The summary above synthesizes these.
No PubMed record mentions this device by name.
Other devices of this type
Also filed under product code NRA.
- Oxford Partial Knee SystemBiomet Manufacturing Corp · PMA 2026
- Oxford Meniscal Unicompartmental Knee SystemBiomet Manufacturing Corp · PMA 2013
- Oxford Unicompartmental Knee SystemBiomet Manufacturing Corp · PMA 2011
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.