PMA device
Oxford Meniscal Unicompartmental Knee System
Biomet Manufacturing Corp · Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing (NRA, Class III) · First FDA decision Apr 21, 2004, newest Jan 4, 2013Knee osteoarthritis
Last checked: Nov 20, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
5
PMA pathway
Device trials
2
Naming "Oxford Meniscal"
MAUDE reports
8
Brand "Oxford Meniscal", since 2015
PubMed studies
17
Mentioning "Oxford Meniscal"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Oxford Meniscal Unicompartmental Knee System
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 5 of 5 decisions filed under this name.
- OXFORD MENISCAL UNICOMPARTMENTAL KNEE SYSTEMPMA supplement
P010014-S039 · Decided Jan 4, 2013 · 60 days after receipt · Normal 180 Day Track No User Fee
Device type: Prosthesis, knee, femorotibial, unicompartmental, semi-constrained, metal/polymer, mobile bearing (NRA) · Orthopedic Surgery
- OXFORD MENISCAL UNICOMPARTMENTAL KNEE SYSTEMPMA supplement
P010014-S027 · Decided Aug 31, 2010 · 60 days after receipt · Normal 180 Day Track No User Fee
Device type: Prosthesis, knee, femorotibial, unicompartmental, semi-constrained, metal/polymer, mobile bearing (NRA) · Orthopedic Surgery
- OXFORD MENISCAL UNICOMPARTMENTAL KNEE SYSTEMPMA supplement
P010014-S005 · Decided Aug 3, 2007 · 640 days after receipt · Normal 180 Day Track No User Fee
Device type: Prosthesis, knee, femorotibial, unicompartmental, semi-constrained, metal/polymer, mobile bearing (NRA) · Orthopedic Surgery
2 more FDA decisions with a free account
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "Oxford Meniscal", any status and sponsor, newest update first.
Biomet Orthopedics, LLCPublic (ZBH)
NCT00578994 · 388 participants · Start Mar 2006 · Primary completion Dec 31, 2019
Device: Oxford® Meniscal Unicompartmental Knee System · For: Osteoarthritis; Avascular Necrosis
Sites: Schaumburg, Illinois; New Albany, Ohio; Cordova, Tennessee · 6 sites in all
- Oxford Partial Knee Kinematics Gait Analysis StudyStatus unknown
The CORE InstituteAcademic, hospital or other
NCT01454908 · 18 participants · Start Apr 2006 · Primary completion Aug 2012
Device: Oxford Partial Knee · For: Medial Knee Compartment Arthritis
Sites: Sun City West, Arizona
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Oxford Meniscal", and for the whole product code for context.
This brand
8 reports: 1 malfunction, 7 injury, 0 death
Whole product code NRA
4,438 reports: 183 malfunction, 4,196 injury, 58 death
Newest reports for this brand
- OXFORD MENISCAL UNICOMInjury
MW5189089 · Received Jun 9, 2026 · Event dated Jan 16, 2026
Device type: Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing (NRA)
Patient problem as coded: Pain
3002806535-2025-00653 · Received Dec 18, 2025 · Event dated Dec 5, 2025
Device type: Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing (NRA)
Device problem as coded: Device Dislodged or Dislocated
Patient problem as coded: Joint Dislocation
0001825034-2017-08906 · Received Oct 17, 2017
Device type: Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing (NRA)
Device problem as coded: Insufficient Device Problem Information
Patient problem as coded: Pain
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-1152-2017 · Started Jan 5, 2016
Reason given: Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product could lead to the cracking and separation of the instrument.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Orthopedic Manual Surgical Instrument (LXH)
Z-1153-2017 · Started Jan 5, 2016
Reason given: Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product could lead to the cracking and separation of the instrument.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Orthopedic Manual Surgical Instrument (LXH)
Z-1154-2017 · Started Jan 5, 2016
Reason given: Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product could lead to the cracking and separation of the instrument.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Driver, Prosthesis (HWR)
19 more recall records with a free account
Published research
The most relevant PubMed records for "Oxford Meniscal"[tiab]. The summary above synthesizes these.
- Unicompartmental Oxford Meniscal knee arthroplasty.
Goodfellow JW, Tibrewal SB, Sherman KP, et al. · J Arthroplasty · 1987
- Oxford meniscal knee.
Miller R, Goodfellow J, O'Connor J · Clin Orthop Relat Res · 1994Comment, Letter
- The Oxford meniscal unicompartmental knee.
Goodfellow J, O'Connor J, Murray DW · J Knee Surg · 2002
- Debridement, Antibiotics, and Implant Retention for an Early Periprosthetic Infection After Unicompartmental Knee Arthroplasty: A Technical Note.
Abdelhameed MA, Khalifa YE, Bakr HM, et al. · Arthroplast Today · 2022
- Soft-tissue balance and alignment in medial unicompartmental knee arthroplasty.
Emerson RH, Head WC, Peters PC · J Bone Joint Surg Br · 1992Comparative Study
- The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty.
Rosenberger RE, Fink C, Quirbach S, et al. · Knee Surg Sports Traumatol Arthrosc · 2008
- Oxford meniscal bearing knee versus the Marmor knee in unicompartmental arthroplasty for arthrosis. A Swedish multicenter survival study.
Lewold S, Goodman S, Knutson K, et al. · J Arthroplasty · 1995Comparative Study, Multicenter Study
- Bilateral Oxford Meniscal Knee arthroplasty.
Sherman KP, Goodfellow J, Tibrewal S, et al. · J R Soc Med · 1985
- Functional biomechanical assessment of the Oxford Meniscal Knee.
Whittle MW, Jefferson RJ · J Arthroplasty · 1989Research Support, Non-U.S. Gov't
- Sagittal plane laxity following knee arthroplasty.
White SH, O'Connor JJ, Goodfellow JW · J Bone Joint Surg Br · 1991
- Oxford medial unicompartmental knee arthroplasty. A survival analysis of an independent series.
Svärd UC, Price AJ · J Bone Joint Surg Br · 2001Evaluation Study
- Kinematic I and Oxford knee arthroplasty. A 5-8-year follow-up study.
Bourne RB, Rorabeck CH, Finlay JB, et al. · J Arthroplasty · 1987Comparative Study
Other devices of this type
Also filed under product code NRA.
- Oxford Partial Knee SystemBiomet Manufacturing Corp · PMA 2026
- Oxford Cementless Partial Knee SystemBiomet Manufacturing Corp · PMA 2024
- Oxford Unicompartmental Knee SystemBiomet Manufacturing Corp · PMA 2011
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.