Device Trial Radar · NCT07941700
AI-Guided eFAST After Liver Surgery
Last checked: Nov 19, 2026Latest source record: Nov 17, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Not yet recruiting
Enrollment
30
Planned (sponsor's estimate)
Start
Dec 2026
Primary completion
Mar 2027
Study completion May 2027
Sponsor
- Lead sponsor
- Oslo University HospitalAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- SINTEF Digital
- First posted
- Nov 17, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Diagnostic
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This study evaluates whether nurses with real-time artificial intelligence (AI) guidance, and without a remote expert, can perform extended Focused Assessment with Sonography in Trauma (eFAST) with diagnostically usable image quality in patients who have recently undergone liver surgery. Each patient is examined twice: first by a nurse using a handheld ultrasound probe with AI guidance, then by a radiologist as reference standard. The study measures image quality, agreement on free fluid between the nurse and the reference standard, and examination duration.
Conditions
- Hemoperitoneum
- Ascites
- Intra-Abdominal Fluid Collection
- Postoperative Complications
Interventions
Real-time AI guidance for eFASTDevice
Software model developed by SINTEF, running on a laptop connected to a Clarius wireless handheld ultrasound probe. Provides real-time structural image recognition to guide the operator.
Nurse-performed eFAST with AI guidanceDiagnostic test
Index test. eFAST performed by a ward nurse with limited ultrasound experience, guided in real time by the AI model, without a remote expert. Windows: right and left upper quadrant, suprapubic (sagittal and transverse), subxiphoid pericardial and bilateral lung. The nurse records a yes/no free fluid assessment per window.
Reference standard: radiologist eFAST or CTDiagnostic test
Independent bedside eFAST performed by an experienced radiologist within one hour after the index test, recorded yes/no per window. CT is the reference when clinically indicated and performed within 24 hours of the ultrasound examinations, and takes precedence when CT and radiologist eFAST disagree. The radiologist also scores image quality of the nurse's stored clips.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Image quality per abdominal eFAST windowTime frame: Within 1 hour after the index examination
- Agreement on free fluid in the abdomenTime frame: Within 24 hours after the index examination (reference eFAST within 1 hour, CT within 24 hours)
- Examination durationTime frame: During the index examination, up to 1 hour
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Oslo University Hospital, Rikshospitalet
Oslo, Oslo, Norway
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.