Device Trial Radar · NCT07923604
nCPAP-NAVA-Backup Versus Standard nCPAP for Severe Apnea in Preterm Infants ≤28 Weeks
Last checked: Nov 19, 2026Latest source record: Nov 10, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Not yet recruiting
Enrollment
25
Planned (sponsor's estimate)
Start
Dec 2026
Primary completion
Dec 2028
Study completion Dec 2028
Sponsor
- Lead sponsor
- University Hospital, GenevaAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Nov 6, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, up to 4 months
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The goal of this clinical trial is to determine whether nasal continuous positive airway pressure (nCPAP) with neurally adjusted ventilatory assist (NAVA) backup ventilation (nCPAP-NAVA-backup mode) reduces the rate of severe apnea in extremely preterm infants ≤28 weeks' gestation compared with standard nasal continuous positive airway pressure (nCPAP mode). Severe apnea episodes is defined as breathing pause with oxygen levels ( SpO2) below 85% lasting at least 5 seconds and/or heart rate (HR) below 100 beats/minute lasting at least 5 seconds. Each participant will receive both interventions in a randomized order, serving as their own control. The total duration of the intervention will be 24h. Each intervention period will last 12 hours. A washout period of 3 hours will be included between intervention periods to minimize potential carryover effects. Randomized sequences to avoid order effects: * Sequence A: nCPAP mode → nCPAP-NAVA-backup mode * Sequence B: nCPAP-NAVA-backup mode →nCPAP mode
Conditions
- Apnea of Prematurity
Interventions
nCPAP-NAVA-backup modeDevice
Standard nasal CPAP delivered via a Servo-n ventilator, with continuous monitoring of the electrical activity of the diaphragm (Edi) through an Edi catheter that also serves as the feeding tube. When an apnea exceeds the preset apnea time, pressure-controlled backup ventilation is triggered automatically. Backup and PEEP settings follow unit standards, and PEEP is kept constant throughout the study. Duration: 12 hours.
nCPAP modeDevice
Standard nasal CPAP delivered via nasal prongs or mask on the same Servo-n ventilator and circuit, with PEEP and FiO₂ managed according to standard clinical practice. Duration: 12 hours.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Number of severe apnea episodes per 9-hour observation periodTime frame: Per 9-hour observation period
Locations
1 site in 1 country. Site status is shown where the registry gives one.
University hospital of Geneva
Geneva, Switzerland
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.