All In MedTech

Device Trial Radar · NCT07916103

HA-Coated and Non-HA Threads for Midface Lifting and Nasolabial Fold Correction

Evaluation of Safety and Effectiveness of APTOS Threads - Absorbable Surgical Sutures Excellence Product Line Models for Mid-face Suspension by Mini-Invasive Surgery to Temporarily Fixate the Cheek Sub-dermis in a Repositioned Site for the Treatment of Moderate to Severe Nasolabial Fold.

Last checked: Nov 19, 2026Latest source record: Nov 9, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedPivotal-lookingRandomized with 144 participants. This is a heuristic, not a regulatory label.

Status

Completed

Enrollment

144

Actual

Start

Jun 19, 2024

Primary completion

Dec 13, 2024

Study completion Mar 1, 2025

Sponsor

Lead sponsor
Aptos, LLC.Academic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Clinical Accelerator
First posted
Nov 4, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Double (participant, outcomes assessor)
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 22 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This randomized study compared absorbable facial lifting threads with and without a hyaluronic acid (HA) coating in 144 adults with moderate-to-severe nasolabial folds, the lines extending from the sides of the nose toward the corners of the mouth. Participants were randomly assigned in a 1:1 ratio to receive either HA-coated or non-HA threads. Follow-up continued for six months. The main assessments evaluated adverse events through Day 30 and changes in nasolabial fold severity at Day 90. Independent evaluators assessed standardized photographs, and participants rated their aesthetic improvement and satisfaction. Additional assessments examined safety and maintenance of improvement through Day 180

Conditions

  • Nasolabial Fold Correction
  • Midface

Interventions

  • HA-coated P(LA/CL) lifting threadsDevice

    The device consists of absorbable, multibarbed monofilament threads made from poly(L-lactide-co-ε-caprolactone) \[P(LA/CL)\] and coated with non-animal-derived, non-cross-linked, medium-molecular-weight sodium hyaluronate. Manufactured by Aptos LLC, Georgia, the models used were Visage Excellence HA (190 mm), Visage Excellence Soft HA (100 mm), and Nano Excellence HA (80 mm). All models had the same number of barbs despite their different lengths and were supplied preloaded in cannulas for subcutaneous tissue repositioning.

  • P(LA/CL) lifting threads without HA coatingDevice

    The device consists of absorbable, multibarbed monofilament threads made from poly(L-lactide-co-ε-caprolactone) \[P(LA/CL)\] without hyaluronic acid coating. Manufactured by Aptos LLC, Georgia, the models used were Visage Excellence (190 mm), Visage Excellence Soft (100 mm), and Nano Excellence (80 mm). All models had the same number of barbs despite their different lengths and were supplied preloaded in cannulas for subcutaneous tissue repositioning.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Incidence of device and procedure related serious adverse events by Day 30 (Month 1) after the implantation procedure.Time frame: From implantation through Day 30.
  2. Reduction in nasolabial fold severity at Day 90 (Month 3) after the implantation procedure in comparison with baseline grading, as assessed by blinded evaluators using the Wrinkles Severity Rating Scale (WSRS).Time frame: Baseline and Day 90 after implantation

Locations

3 sites in 1 country. Site status is shown where the registry gives one.

  • "Total Charm Piazza",15 Vakhtang Gorgasali Street

    Batumi, Georgia

  • "Total Charm LTD", Orbeliani Str #18

    Tbilisi, Georgia

  • "Total Charm Vake", 87B Zakaria Paliashvili Street

    Tbilisi, Georgia

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.