Device Trial Radar · NCT07903142
Comparison of High-Intensity and Conventional Physical Therapy in Musculoskeletal Disorders
Last checked: Nov 20, 2026Latest source record: Oct 29, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Not yet recruiting
Enrollment
60
Planned (sponsor's estimate)
Start
Oct 15, 2026
Primary completion
Jun 30, 2027
Study completion Jun 30, 2027
Sponsor
- Lead sponsor
- BTL Industries Ltd.Not on our public-company list
- Sponsor type
- Industry
- First posted
- Oct 29, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This pilot randomized controlled trial aims to compare the clinical effectiveness of advanced high-intensity physical therapy modalities with conventional physical therapy in patients suffering from musculoskeletal disorders. The study focuses on three anatomical areas: lower back, shoulder, and knee. Participants will be randomized into two arms and will undergo 5 therapeutic sessions.
Conditions
- Low Back Pain
- Radicular Syndrome
- Sacroiliac Joint Dysfunction
- Shoulder Impingement Syndrome
- Rotator Cuff Tendinopathy
- Shoulder Osteoarthritis
- Acromioclavicular Joint Osteoarthritis
- Knee Osteoarthritis
- Patellofemoral Pain Syndrom
Interventions
Repetitive Peripheral Magnetic Stimulation (rPMS)Device
Application of high-intensity repetitive peripheral magnetic stimulation using the Super Inductive System (SIS) device. The parameters (frequency, intensity) are tailored to the treated anatomical area (knee, shoulder, or lumbar spine) aiming for a motor-threshold intensity (for conditions like gonalgia, impingement syndrome, and chronic lumbosacral syndrome). The therapy is applied over 5 sessions.
High-Intensity Laser Therapy (HIL)Device
Application of a high-intensity laser device. The treatment parameters are set for analgesia, specifically tailored to the anatomical region. The therapy is applied over 5 sessions.
Extracorporeal Shockwave Therapy (ESWT)Device
Application of radial extracorporeal shockwave therapy to the affected tissue. Parameters (pressure, frequency, no. of shocks) are region-specific. The therapy is applied over 5 sessions.
Pulsed Electromagnetic Field Therapy (PEMF)Device
Application of conventional low-induction pulsed electromagnetic field therapy using a solenoid applicator. The treatment duration is set to 30 minutes per session, with programs specific to the anatomical region (e.g., gonalgia, periarthritis humeroscapularis, lumbosacral syndrome). The therapy is applied over 5 sessions.
Therapeutic Ultrasound (USN)Device
Application of therapeutic ultrasound to the target muscles or tissues. Parameters vary by region (frequency, duty factor, intensity), always applied for 7 minutes per session. The therapy is applied over 5 sessions.
Electrotherapy (Medium-Frequency Currents)Device
Application of medium-frequency electrotherapy using a tetrapolar setup with an isoplanar vector field. The treatment duration is 20 minutes per session, targeting the affected anatomical region. The therapy is applied over 5 sessions.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Change in Pain Intensity (VAS)Time frame: Immediately before each treatment session (Sessions 1 through 5) and immediately following the 5th (final) treatment session (over a period of up to approximately 3 weeks)
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Faculty of Physical Education and Sport, Charles University
Prague, Prague, Czechia
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.