Last checked: Nov 20, 2026Latest source record: Oct 19, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruiting

Status

Not yet recruiting

Enrollment

18

Planned (sponsor's estimate)

Start

Dec 2026

Primary completion

Dec 2027

Study completion Dec 2027

Sponsor

Lead sponsor
Boston UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Oct 19, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 22 years, up to 35 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Clear aligners are thin, transparent plastic trays that straighten teeth gradually and are a popular, more discreet alternative to traditional braces. To help the traOptionalys grip and move the teeth, dentists usually bond small tooth-colored bumps, called "attachments," onto the front or back surfaces of the teeth. Although aligners work well for many types of tooth movement, they are much less reliable at turning (rotating) teeth that are twisted out of position, especially rounded teeth such as premolars and canines. Teeth often turn less than planned or tip and shift in unwanted directions. As a result, patients may need extra sets of aligners or a period of conventional braces, which takes away the main reason many people choose aligners. This study will evaluate the clinical performance of the proposed occlusal attachment designed by the investigators, quantifying rotational correction along with any unintended movements of the target and adjacent teeth. The study is not designed as a device trial of the aligner system, but as an evaluation of a modified attachment configuration within routine clear aligner treatment. The Primary Objective is to determine the degree of rotational correction that can be achieved in rotated canines and/or premolars using clear aligners with occlusal surface attachments. The Secondary Objective is to assess any unintended tooth movements, including buccolingual tipping, mesiodistal translation and vertical displacement.

Conditions

  • Rotation of Tooth

Interventions

  • novel attachment configurationDevice

    Standard clear aligner therapy using a commercially available system (e.g., Invisalign or equivalent) in which at least one rotated canine or premolar per subject will receive a conventional attachment placed on the occlusal surface and be designated as the index tooth for outcome assessment. No experimental materials will be used; only the attachment position differs from standard practice, and the aligners themselves are FDA- cleared devices manufactured according to existing protocols.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change in tooth rotationTime frame: baseline, 12 months

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Boston University Henry M Goldman School of Dental Medicine, Orthodontic Clinic

    Boston, Massachusetts

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.