All In MedTech

Device Trial Radar · NCT07857330

Ultrasound Guided Leadless Pacemaker Implantation

A Study on the Feasibility of a Novel Guidance Method for Leadless Pacemaker Implantation

Last checked: Nov 20, 2026Latest source record: Nov 19, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruitingPivotal-lookingRandomized with 288 participants. This is a heuristic, not a regulatory label.

Status

Not yet recruiting

Enrollment

288

Planned (sponsor's estimate)

Start

Oct 20, 2026

Primary completion

Apr 20, 2028

Study completion Jul 20, 2028

Sponsor

Lead sponsor
China National Center for Cardiovascular DiseasesGovernment (non-federal)
Sponsor type
Government (non-federal)
First posted
Oct 5, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The leadless pacemaker is a novel pacing technology that has emerged in recent years. Compared with conventional lead pacemakers, its design avoids many complications associated with leads and pacemaker pockets, including lead fracture, pocket infection, and venous access stenosis. Because of its small size and the absence of a pacemaker pocket or pacing lead, the leadless pacemaker is particularly suitable for patients with contraindications to conventional pacemaker implantation, including patients undergoing hemodialysis, patients with recurrent pocket infection, and patients without suitable vascular access. Currently, leadless pacemaker implantation is performed primarily under fluoroscopic guidance. Fluoroscopy provides real-time intraoperative anatomical localization information but places high demands on the operator's technical skills and the precise intraoperative positioning of the pacemaker. However, procedures performed under fluoroscopic guidance require dedicated procedure rooms and radiation-generating equipment. Such large-scale equipment is expensive, and it requires special protective measures that make the surrounding walls, doors and windows meet the protection standards, so as not to cause harm to the surrounding environment and personnel. When procedures are performed under fluoroscopic guidance in dedicated catheterization laboratories, both operators and patients are exposed to potential health risks, and fluoroscopy-guided procedures are contraindicated in some pregnant women. In addition, X-ray imaging remains two-dimensional, and visualization may be inadequate in some patients because of individual anatomical variation, potentially increasing procedural difficulty. Therefore, exploring a radiation-free, real-time, and accurate guidance method has become a key approach to improving the success rate and safety of leadless pacemaker implantation.

Conditions

  • Leadless Pacemaker
  • Transthoracic Echocardiography

Interventions

  • Transthoracic echocardiography-guidedProcedure

    1. Preoperative Preparation: Perform preoperative assessment using TTE to evaluate cardiac chamber anatomy and ultrasound image quality. Individually adjust the ultrasound system settings according to patient characteristics and record key anatomical landmarks. 2. Intraoperative Procedure: Use real-time TTE to guide the pacemaker delivery catheter through the right atrium to the right ventricle. Observe the catheter trajectory and identify the target region. After confirming electrode contact, complete pacemaker fixation and record the imaging findings in real time.

  • Conventional fluoroscopy-guidedProcedure

    Leadless pacemaker implantation is performed under fluoroscopic guidance in accordance with current standard clinical practice.

  • Leadless pacemakerDevice

    Commercially available leadless pacemaker system implanted in all study participants.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Percentage of participants with successful Micra leadless pacemaker implantationTime frame: During Procedure

Locations

No sites are listed on the registry yet.

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.