Device Trial Radar · NCT07815314
A Prospective Study Comparing CSF Shunt Flow Between "Virtual Off" and "Flow Permissive" Shunt Valve Settings Using a Wireless, Noninvasive Shunt Flow Sensor
Last checked: Nov 19, 2026Latest source record: Nov 18, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
85
Planned (sponsor's estimate)
Start
Sep 23, 2026
Primary completion
Jan 2027
Study completion Feb 2027
Sponsor
- Lead sponsor
- Rhaeos, Inc.Not on our public-company list
- Sponsor type
- Industry
- Collaborators
- OSF Healthcare System; Johns Hopkins University; SUNY Research Foundation; Northwestern Memorial Hospital; Springfield Clinic
- First posted
- Sep 11, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Screening
- FDA-regulated device
- Yes
- Who can join
- All sexes
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Hydrocephalus is commonly treated with a cerebrospinal fluid (CSF) shunt, a device that drains excess fluid from the brain. However, shunts can stop working over time, and determining whether fluid is flowing through a shunt can be difficult. Current diagnostic methods may require imaging studies or invasive procedures, which can be time-consuming, costly, or uncomfortable for patients. The purpose of this study is to evaluate the performance of the Rhaeos Shunt Monitoring System (RSMS), an investigational wireless, noninvasive device designed to detect flow in implanted CSF shunts. The study will compare RSMS directly with ShuntCheck III, an FDA-cleared noninvasive device that is also used to assess CSF shunt flow. Both devices are placed on the skin over the shunt and use thermal sensing technology to evaluate whether fluid is flowing through the shunt. Approximately 85 pediatric and adult participants with an existing ventricular CSF shunt will be enrolled. Some participants with programmable shunt valves will have their valve temporarily adjusted to a manufacturer-provided "virtual off" setting, which is intended to substantially restrict shunt flow. These participants may also undergo measurements at their normal valve setting. Other participants will only undergo measurements at their normal valve setting. During the study visit, participants will undergo shunt flow assessments with both RSMS and ShuntCheck III. The order in which the devices are used will be randomized. Device measurements are collected while participants are seated upright, and participants and their treating clinicians will remain blinded to the measurement results. The study devices will not be used to make treatment decisions, and participation will not alter standard medical care. Adverse events associated with device use or valve adjustments will be monitored and recorded. The primary goal of the study is to compare the performance of RSMS and ShuntCheck III in assessing shunt flow with flow-permissive ("valve normal") and restricted-flow ("virtual off") settings. Results from this study may help support the future development of a noninvasive tool to aid neurosurgeons in assessing CSF shunt flow. Participants are not expected to receive a direct medical benefit from taking part in the study.
Conditions
- Hydrocephalus
Interventions
Rhaeos Shunt Monitoring System (RSMS)Device
The Rhaeos Shunt Monitoring System (RSMS) is an investigational, wireless, noninvasive thermal flow detection device that is applied to the skin overlying an implanted cerebrospinal fluid (CSF) shunt. The device uses controlled thermal energy and temperature sensors to detect thermal patterns associated with CSF flow. Measurements are obtained using a tablet application, and device results are encoded to maintain blinding. The device is used for research purposes only and is not used to guide clinical care.
ShuntCheck IIIDevice
ShuntCheck III is an FDA-cleared, noninvasive thermal flow detection device used as the predicate comparator. The device uses transcutaneous thermal dilution produced by an instant cold pack and a disposable thermosensor array applied over the implanted CSF shunt to detect shunt flow. Measurements are obtained using the manufacturer's software, and results are encoded to maintain blinding. The device is used for comparison with the investigational device and is not used to guide clinical care during the study.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Sensitivity of the Rhaeos Shunt Monitoring System Compared With ShuntCheck IIITime frame: Day 1 (study visit)
- Rate of Measured Flow in Flow Permissive Shunt Settings of the Rhaeos® Shunt Monitoring System Compared With ShuntCheck IIITime frame: Day 1 (study visit)
Locations
4 sites in 1 country. Site status is shown where the registry gives one.
Northwestern Medical Group
Chicago, Illinois · Recruiting
Rhaeos, Inc
Chicago, Illinois · Recruiting
The Johns Hopkins Hospital
Baltimore, Maryland · Recruiting
1 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.