Status
Not yet recruiting
Enrollment
32
Planned (sponsor's estimate)
Start
Sep 2026
Primary completion
May 2027
Study completion Dec 2028
Sponsor
- Lead sponsor
- Mayo ClinicAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- Icahn School of Medicine at Mount Sinai; University of Colorado, Denver; Stanford University
- First posted
- Sep 8, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- Yes
- Who can join
- Female only, from 18 years, up to 45 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Suboptimal glycemic control during pregnancy contributes to adverse maternal and fetal health outcomes and previous automated insulin delivery (AID) studies have demonstrated improvement in glucose control across all ages and sexes irrespective of past treatment modality or diabetes duration with no increase in hypoglycemia. However, very few studies evaluating AID system use in pregnancy have been performed in the US and no AID systems are currently approved for use during pregnancy. The objective of this trial is to evaluate the safety and efficacy of THE TWIIST™ system that enables the selection of pregnancy-specific glucose targets. This phase 3 pivotal trial will assess the system's performance in pregnant people with pre-existing type 1 diabetes in the US, starting as early as pregnancy confirmation, continuing throughout the pregnancy including delivery and up to 6 weeks post-partum.
Conditions
- Type 1 Diabetes
- Pregnancy
Interventions
Automated Insulin Delivery (AID)Device
The AID control algorithm, that will be used during the study employs a model-based predictive control algorithm to forecast future glucose levels. This predictive model accounts for the impact of delivered insulin, user-entered carbohydrates, and incorporates two short-term adaptations: "glucose momentum" and "retrospective correction." These features work to optimize glucose management with precision. The impact of carbohydrates is calculated based on the user-defined insulin-to-carbohydrate ratio and insulin sensitivity factor (ISF), while the insulin effect is governed by the ISF itself. The system then dynamically adjusts insulin delivery, aiming to bring glucose levels in line with the midpoint of the user's personalized glucose target range. Loop fine-tunes insulin delivery by increasing or decreasing the basal insulin rate, as needed, each time a new CGM value is received.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Time in Range 60-140 mg/dL per nightTime frame: 30 weeks
Locations
4 sites in 1 country. Site status is shown where the registry gives one.
Stanford University
Stanford, California
University of Colorado, Anschutz Medical Campus
Aurora, Colorado
Mayo Clinic
Rochester, Minnesota
1 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.