Comparative Study of the Tomey FT-1000, and Goldmann Applanation Tonometer (GAT)

Last checked: Nov 19, 2026Latest source record: Nov 12, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

40

Actual

Start

Sep 23, 2026

Primary completion

Oct 9, 2026

Study completion Oct 9, 2026

Sponsor

Lead sponsor
Tomey CorporationNot on our public-company list
Sponsor type
Industry
First posted
Sep 4, 2026

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
Yes
Who can join
All sexes, from 22 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

This study is intended to evaluate the agreement between Intraocular pressure(IOP) measurements obtained with the FT-1000 non-contact tonometer and a GAT to confirm the feasibility of the measurement procedures. This is a prospective comparative study that will be conducted at one clinical site in the United States. Subjects who sign an informed consent form and fulfill all inclusion and exclusion criteria will undergo FT-1000 measurements followed by Goldmann applanation tonometry during a single study visit. The primary analysis will be performed using one preselected study eye from each subject. Measurements from the fellow eye, when available, may be summarized as exploratory analyses but will not contribute to the primary effectiveness analysis. In general, descriptive statistics (n, mean, standard deviation, median, minimum and maximum) will be used to summarize continuous variables. Frequencies and percentages will be used to summarize categorical variables. The number of accepted scans and the total number of scans evaluated will be summarized by scan type, device, and subject population. Agreement between the FT-1000 and the Goldmann applanation tonometer will be evaluated using the study eye measurements by calculating the mean difference, standard deviation (SD), 95% limits of agreement (LOA), Bland-Altman plots, Deming regression, and Pearson correlation coefficient. Exploratory analyses may also be performed using fellow-eye measurements.

Conditions

  • Glaucoma

Interventions

  • Non Contact Tonometer and Applanation TonometerDevice

    Intraocular pressure measurement by non-contact tonometer and applanation tonometer.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Agreement of the Intraocular pressure (IOP) mmHg between the test devices and predicate deviceTime frame: Through study completion, approximately 3 days
  2. Safety of the test devicesTime frame: Through study completion, approximately 3 days

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Rovia East Coast Institute for Research Jacksonville - Eye Center

    Jacksonville, Florida

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.