All In MedTech

Device Trial Radar · NCT07795671

Rotational Stability of Two Soft Toric Contact Lens Designs

Comparison of Rotational Behavior of Soft Toric Contact Lenses With Different Stabilization Designs and Their Association With Ocular Biometric Parameters

Last checked: Nov 19, 2026Latest source record: Sep 1, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

40

Actual

Start

May 2, 2026

Primary completion

Jul 1, 2026

Study completion Jul 1, 2026

Sponsor

Lead sponsor
Bozok UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Aug 31, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Crossover
Masking
None
Primary purpose
Other
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 50 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This study compared the rotational behavior of two commercially available soft toric contact lenses with different stabilization designs and explored whether ocular biometric and refractive characteristics were associated with lens rotation. Contact lens-naïve adults underwent baseline ocular biometry and were scheduled for two separate lens-fitting sessions in randomized order. Lens rotation was measured 30 minutes after insertion in primary, right, left, upward, and downward gaze using slit-lamp biomicroscopy. The study was designed as a two-period crossover comparison.

Conditions

  • Astigmatism

Interventions

  • Acuvue Oasys for AstigmatismDevice

    Commercially available soft toric contact lens composed of senofilcon A, with an 8.6-mm base curve and 14.5-mm diameter, using an accelerated stabilization design.

  • Air Optix for AstigmatismDevice

    Commercially available soft toric contact lens composed of lotrafilcon B, with an 8.7-mm base curve and 14.5-mm diameter, using a modified periballast stabilization design.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Overall Mean Absolute Contact Lens RotationTime frame: 30 minutes after lens insertion during each fitting session

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Yozgat Bozok University Research and Application Hospital

    Yozgat, Yozgat, Turkey (Türkiye)

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.