Pulsed Field Ablation for Atrial Fibrillation Using the VARIPULSE™ Catheter

Last checked: Nov 19, 2026Latest source record: Aug 21, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruiting

Status

Not yet recruiting

Enrollment

40

Planned (sponsor's estimate)

Start

Sep 2026

Primary completion

Sep 2028

Study completion Sep 2028

Sponsor

Lead sponsor
Radboud University Medical CenterAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Amsterdam UMC
First posted
Aug 21, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Rationale: Effectiveness of thermal ablation techniques for pulmonary vein isolation, to treat atrial fibrillation (AF), are hampered by frequent pulmonary vein reconnection and risks of collateral tissue injury. Pulsed field ablation (PFA) offers a non-thermal, tissue-specific alternative that may provide more durable isolation while also reducing procedural risks. While early data for the CE-marked VARIPULSE™ PFA system are promising, long-term lesion durability remains mostly unquantified. To obtain a definitive estimate of PFA effectiveness, a systematic invasive re-mapping approach is required. Advanced cardiac magnetic resonance (CMR) imaging can quantify atrial fibrosis after PVI across different ablation modalities, but it is unknown how well these imaging findings correspond with invasive electrical mapping. In the current study, CMR serves as a complementary modality to explore whether imaging-based tissue changes align with invasively confirmed long-term isolation. Objective: The primary objective is to evaluate the long-term durability of pulmonary vein isolation (PVI) using the VARIPULSE™ Pro PFA system, as defined by the rate of electrical reconnection during systematic invasive re-mapping at three months. Study design: Prospective multicenter intervention study. Study population: Patients ≥ 18 years old, eligible for primary PVI according to ESC guidelines, without contraindications for gadolinium-based contrast-enhanced CMR imaging. Intervention: Patients will undergo PVI using PFA with the VARIPULSE™ catheter. After 3-4 months, a re-map procedure will be performed to assess lesion durability and to re-isolate any electrical reconnections. Main study parameters/endpoints: Primary outcome measure: Patient-level PV lesion durability. Secondary outcome measures: Percentage chronic isolation for each PV; Location of reconnection during re-map and lesion characteristics; Presence, location, size, volume and composition of acute (within 72 hours) and chronic (3 months) ablation lesions and collateral tissue damage on CMR (in the atrial wall and surrounding structure); Procedural fluoroscopy time and radiation dose; Percentage direct isolation for each pulmonary vein (PV); Acute PV reconnection for each PV; Percentage freedom from atrial achyarrhythmias at 12 months follow-up; Incidence of procedure related adverse events. Nature and extent of the burden and risks associated with participation, benefit and group relatedness: Participation involves standard PVI care with additional CMR imaging and an invasive re-map procedure. Early studies show that PFA with the VARIPULSE™ catheter is safe, and the extra imaging adds only minimal burden or risk. The re-map study carries the same risks as standard ablation. Overall, the study is expected to provide valuable insights that may further improve patient care and outcomes in atrial fibrillation.

Conditions

  • Atrial Fibrillation (AF)

Interventions

  • Pulsed Field Ablation (PFA) with the VARIPULSE™ catheterDevice

    Pulsed field ablation (PFA) is a non-thermal catheter ablation technology that creates myocardial lesions through irreversible electroporation by delivering short, high-voltage electrical pulses. This mechanism preferentially affects cardiomyocytes while minimizing damage to adjacent structures such as the esophagus, phrenic nerve, and pulmonary veins. The VARIPULSE™ catheter is a variable-loop, multielectrode, biphasic PFA catheter integrated with the CARTO® 3 electroanatomical mapping system. It is designed to perform pulmonary vein isolation by delivering pulsed electrical fields around the pulmonary vein ostia. In this study, the VARIPULSE™ catheter will be used for pulmonary vein isolation in patients with atrial fibrillation, followed by systematic invasive remapping to assess long-term pulmonary vein isolation durability and reconnection rates.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Patient-level pulmonary vein lesion durabilityTime frame: Determined during invasive re-mapping, performed 3-4 months after pulmonary vein isolation (PVI)

Locations

No sites are listed on the registry yet.

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.