All In MedTech

Device Trial Radar · NCT07778823

Augmented Reality-Cardiopulmonary Resuscitation Support for Pediatric Resuscitation

AR-CPR: Large-Scale Simulation-Based Testing of a Novel Augmented Reality Point of Care Chest Compression Feedback System

Last checked: Nov 19, 2026Latest source record: Aug 26, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

RecruitingPivotal-lookingRandomized with 252 participants. This is a heuristic, not a regulatory label.

Status

Recruiting

Enrollment

252

Planned (sponsor's estimate)

Start

Jun 29, 2025

Primary completion

Mar 31, 2028

Study completion Jun 30, 2028

Sponsor

Lead sponsor
Johns Hopkins UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
The Hospital for Sick Children; Columbia University; Brown University; Children's Hospital of Philadelphia; Johns Hopkins All Children's Hospital; Children's Medical Center Dallas; Baylor College of Medicine; Agency for Healthcare Research and Quality (AHRQ)
First posted
Aug 21, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Other
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

This study evaluates whether an augmented reality cardiopulmonary resuscitation feedback system (AR-CPR) can support health care providers in delivering high-quality chest compressions during pediatric cardiac arrest. AR-CPR provides real-time visual feedback on chest compression rate, depth, and recoil through a head-mounted augmented reality display. In this randomized, multicenter, international, simulation-based non-inferiority study, health care providers perform chest compressions during an 18-minute simulated pediatric cardiac arrest. Participants are assigned to receive either real-time feedback from AR-CPR or coaching from a trained human CPR coach. The primary objective is to determine whether the percentage of chest compressions meeting guideline targets for both rate and depth with AR-CPR is non-inferior to that achieved with human CPR coaching.

Conditions

  • Cardiac Arrest (CA)
  • Pediatric Cardiac Arrest (Simulated)
  • Cardiopulmonary Resuscitation (CPR)

Interventions

  • AR-CPRDevice

    AR-CPR is a real-time augmented reality CPR feedback system designed to guide chest compression performance during pediatric cardiac arrest. The system uses a compression sensor containing an inertial measurement unit (IMU) and force-sensitive resistor (FSR) connected to a microcontroller. Sensor data are relayed to a Raspberry Pi 5 microcomputer running custom AR-CPR Coach software, which calculates chest compression rate, depth, and recoil. These metrics are transmitted wirelessly to a Vuzix M400 head-mounted display. The augmented reality interface provides numerical values and visual cues within the user's field of view. When performance is outside established targets, the system provides qualitative feedback and, for persistent deviations, escalates to explicit goal-directed instructions.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Percentage of Overall Excellent CPRTime frame: Up to 18 minutes

Locations

8 sites in 2 countries. Site status is shown where the registry gives one.

  • All Childrens Hopsital

    St. Petersburg, Florida · Recruiting

  • Johns Hopkins Children's Center

    Baltimore, Maryland · Recruiting

  • Columbia University Vagelos College of Physicians and Surgeons

    New York, New York · Recruiting

5 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.