All In MedTech

Device Trial Radar · NCT07762053

Clinical Investigation of Eye C Better's Photobionic Intraocular Pressure Biomonitor Tonometer

A Prospective, Non-Randomized, Single-Center Clinical Investigation of the Safety and Performance of Eye C Better's Photobionic IOP Biomonitor Tonometer (PIB)

Last checked: Nov 21, 2026Latest source record: Sep 10, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Active, not recruiting

Status

Active, not recruiting

Enrollment

15

Planned (sponsor's estimate)

Start

Aug 31, 2026

Primary completion

Sep 2026

Study completion Sep 2026

Sponsor

Lead sponsor
EyeCBetter CorporationNot on our public-company list
Sponsor type
Industry
Collaborators
National Eye Institute (NEI)
First posted
Aug 13, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
Yes
Who can join
All sexes, from 18 years, up to 100 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

The device being studied in this research is the investigational PIB, a tool designed to measure eye pressure without touching the eye. The device uses a very low-power, eye-safe infrared light and a gentle sound signal to detect tiny movements on the white part of the eye. A camera records these movements, and a computer analyzes the information to estimate eye pressure. The test takes only a few seconds and does not require eye drops or contact with the eye. The device rests near your face using a chin and forehead support, like equipment used in an eye doctor's office. The PIB aims to provide the following possible benefits over the devices doctors may be using now including the GAT: * No touching of the eye to lower the risk of infection and discomfort * Improved accuracy and precision * Faster eye pressure measurements * Measurements that may be done by a patient at home without the need for a doctor * A low-cost eye pressure measurement device that may be used in areas where there are fewer doctors The PIB device is investigational, which means that it is not approved by the Food and Drug Administration (FDA). The GAT device has been approved by the FDA.

Conditions

  • Elevated Intraocular Pressure (IOP)

Interventions

  • Photobionic IOP Tonometer (PIB)Device

    This study aims to evaluate the repeatability of IOP as measured in human eyes using Eye C Better Corp's Photonic IOP Biomonitor (PIB) Tonometer. PIB is a novel methodology allowing high-precision, non-contact, non-air puff, reproducible and semi-continuous IOP monitoring without clinician interpretation. PIB is based on observations in fish and porcine eyes, that sound waves induce scleral oscillations in an IOP dependent fashion. PIB measures these nanometric oscillations by monitoring speckle patterns generated with an eye-safe infrared laser reflected by the sclera. A high-speed camera records the speckle patterns and physical modelling combined with machine learning (ML) algorithms process this data to infer IOP. This technology will be configurable as a physician office-based platform and as a home-based device allowing the patient to self-measure IOP's frequently outside of the clinical setting for earlier detection and treatment of increased IOP.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. PIB repeatability in human eyesTime frame: Timeframe from enrollment to end of test will be a maximum of 60 minutes

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Acuity Eye Group

    La Quinta, California

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.