All In MedTech

Device Trial Radar · NCT07758647

NO-Meal Announcement in Automated Insulin Delivery (Open-source and Commercial) Systems

Last checked: Nov 19, 2026Latest source record: Aug 11, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruiting

Status

Not yet recruiting

Enrollment

33

Planned (sponsor's estimate)

Start

Oct 1, 2026

Primary completion

Sep 1, 2029

Study completion Dec 31, 2029

Sponsor

Lead sponsor
Institut de Recherches Cliniques de MontrealAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Stanford University; University of Alberta
First posted
Aug 11, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Crossover
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Automated insulin delivery (AID) systems are the current gold standard for the management of type 1 diabetes (T1D), improving glycemic control, reducing hypoglycemia, and decreasing treatment burden. Although both commercial AID (C-AID) and open-source AID (OS-AID) systems have demonstrated significant clinical benefits, direct randomized comparisons between these systems remain scarce. Moreover, an important limitation of currently available AID systems is their reliance on user-initiated meal announcements and carbohydrate counting, which remain major contributors to postprandial dysglycemia and treatment burden. While emerging evidence suggests that AID systems may partially compensate for missed meal announcements, their comparative performance under these challenging real-world conditions is unknown. The NOMAD study is an international, multicenter, open-label, randomized, non-inferiority crossover trial designed to compare an open-source AID system with commercially available AID systems (including Tandem Control-IQ and Omnipod 5) in adults with type 1 diabetes currently using an open-source AID system. The study specifically evaluates glycemic outcomes following standardized unannounced meal challenges performed under free-living conditions. A total of 33 participants will be enrolled and complete two 4-week intervention periods, each consisting of a 2-week run-in phase followed by a 2-week data collection phase, with crossover between treatment arms. Participants will continue using their own Dexcom G6 or Dexcom G7 continuous glucose monitoring system throughout the study. The primary outcome is the percentage of time spent in the target glucose range (3.9-10.0 mmol/L) during the 4 hours following standardized unannounced meal challenges. Secondary outcomes include additional CGM metrics (time above and below range, glucose variability, mean glucose, and GMI), insulin delivery characteristics, and patient-reported outcomes evaluating treatment satisfaction, usability, and diabetes-related burden.

Conditions

  • Type 1 Diabetes (T1D)

Interventions

  • Open-Source Automated Insulin Delivery (OS-AID)Device

    Participants will use their own OS-AID system, including Loop, AndroidAPS, or OpenAPS, in combination with a compatible insulin pump and Dexcom G6 or Dexcom G7 continuous glucose monitoring (CGM). These systems use open-source algorithms to automatically adjust insulin delivery based on real-time CGM data through adaptive basal insulin modulation and, depending on the platform, automated correction boluses. Participants will continue using their established OS-AID settings throughout the intervention period without software updates and will be asked to perform two unannounced meal-challenges.

  • Commercial Automated Insulin Delivery (C-AID)Device

    Participants will use a commercially available hybrid closed-loop AID system compatible with Dexcom G6 or Dexcom G7 CGM. Depending on study allocation and participants' usual device, the commercial system will include Tandem t X2 with Control-IQ technology or Omnipod 5. Participants not already using a compatible commercial AID system will receive study equipment and standardized training before initiating the intervention. Commercial AID systems automatically adjust insulin delivery based on continuous glucose measurements using manufacturer-specific algorithms while continuing to recommend user-initiated meal announcements and boluses for optimal performance.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Percentage of time in target glucose range during the 4 hours following unannounced meal challengesTime frame: During the final 2 weeks of each 4-week intervention period (following the run-in phase).

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Institut de Recherches Cliniques de Montréal

    Montreal, Quebec, Canada

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.