Ultra-early Identification of Futile Recanalization After Reperfusion Therapy in Acute Ischemic Stroke Based on Cerebral Autoregulation Monitoring

Ultra-early Identification of Futile Recanalization After Reperfusion Therapy in Acute Ischemic Stroke Based on Cerebral Autoregulation Monitoring: a Multicenter, Prospective, Interventional Study

Last checked: Nov 19, 2026Latest source record: Nov 9, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

227

Planned (sponsor's estimate)

Start

Jul 31, 2026

Primary completion

Jan 31, 2027

Study completion Feb 5, 2027

Sponsor

Lead sponsor
Beijing Shijitan Hospital, Capital Medical UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Aug 5, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This multicenter, prospective, and interventional diagnostic accuracy study enrolls patients undergoing thrombectomy with intraoperative cerebral autoregulation monitoring and follows them up at predefined time points up to 90 days post-enrollment.This study aims to evaluate a monitoring system based on cerebral autoregulation function and explore its predictive value for adverse neurological outcomes at the ultra-early stage following mechanical thrombectomy.

Conditions

  • Acute Ischemic Stroke
  • Cerebral Autoregulation

Interventions

  • NIRS-based cerebral oxygenation and blood pressure monitoringDevice

    Bedside multimodal cerebral autoregulation monitoring performed immediately after successful mechanical thrombectomy (mTICI 2b-3). Monitoring includes continuous near-infrared spectroscopy (NIRS) to record cerebral oxygen saturation and continuous noninvasive or invasive arterial blood pressure measurement for 25-30 minutes. Cerebral oxygenation index (COx) is calculated as a moving Pearson correlation coefficient between mean arterial pressure and cerebral oxygen saturation over 30 consecutive 10-second epochs (300 seconds). COx ≥ 0.3 indicates impaired cerebral autoregulation, while COx \< 0.3 indicates preserved autoregulation. Changes in cerebral oxygen saturation before and after carotid compression are also used to assess autoregulatory.

  • Carotid compression testProcedure

    A carotid compression test is performed by compressing the common carotid artery at the lower one-third of the neck (avoiding the carotid sinus) against the transverse process of C6 until pulsation disappears for 5-10 seconds, followed by release. If the brain oxygen saturation has increased compared to before the test, it indicates that the brain's automatic blood flow regulation function is intact; conversely, if it has decreased, it is regarded as a damaged automatic blood flow regulation function of the brain.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Distribution of Modified Rankin scaleTime frame: 90±7days

Locations

4 sites in 1 country. Site status is shown where the registry gives one.

  • Beijing Shijitan Hospital, Capital Medical University

    Beijing, China · Recruiting

  • Central Hospital of Dalian University of Technology (Dalian Municipal Central Hospital)

    Dalian, China · Recruiting

  • The First Affiliated Hospital of Harbin Medical University

    Heilongjiang, China · Recruiting

1 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.