All In MedTech

Device Trial Radar · NCT07689838

In-Vivo Diagnostic Accuracy and Repeatability of Root ZX3 for Working-Length Determination in Single-Rooted Teeth: Agreement With CBCT and Microscopic Validation

Last checked: Nov 19, 2026Latest source record: Nov 4, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedResults posted on the registry

Status

Completed

Enrollment

41

Actual

Start

Oct 19, 2025

Primary completion

Feb 28, 2026

Study completion Jun 30, 2026

Sponsor

Lead sponsor
Riyadh Elm UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Jul 8, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

This study evaluated the accuracy and repeatability of the Root ZX3 electronic apex locator for working-length determination in 77 single-rooted permanent teeth. Root ZX3 measurements obtained before extraction were compared with CBCT measurements and direct microscopic measurements of the apical foramen after extraction.

Conditions

  • Apical Periodontitis
  • Pulp Disease, Dental
  • Device Reliability
  • Device Performance

Interventions

  • Root ZX3 Electronic Apex LocatorDevice

    The Root ZX3 electronic apex locator was used for in vivo working-length determination during primary nonsurgical root canal treatment. Following access preparation, preflaring, and irrigation, a size 10 or 15 K-file was advanced through the canal until the device indicated the apical foramen. A stable reading for at least 5 seconds was required, and the file position was measured from a standardized coronal reference point. The measurement was repeated under identical conditions to evaluate intraoperator repeatability. After extraction, the Root ZX3 measurements were compared with the actual working length determined by direct microscopic visualization of the apical foramen. CBCT working-length measurements were also obtained independently for comparison.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Diagnostic Accuracy of the Root ZX3 Electronic Apex Locator for Working-length DeterminationTime frame: during endodontic treatment before tooth extraction

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Abier alhekeir

    Riyadh, Riyadh Region, Saudi Arabia

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.