Effect of Continuous Supraglottic Oxygen Insufflation Via Video Laryngoscope Blade on Apneic Oxygenation During Tracheal Intubation Under General Anesthesia
Last checked: Nov 19, 2026Latest source record: Nov 16, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Not yet recruiting
Enrollment
150
Planned (sponsor's estimate)
Start
Nov 14, 2026
Primary completion
Jul 1, 2029
Study completion Jul 1, 2029
Sponsor
- Lead sponsor
- Affiliated Hospital of Jiaxing UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- The Second Affiliated Hospital of Jiaxing University
- First posted
- Jun 23, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Triple (participant, care provider, outcomes assessor)
- Primary purpose
- Prevention
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years, up to 75 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This study is a prospective, randomized controlled clinical trial aimed at investigating the efficacy and safety of a novel oxygenating video laryngoscope blade during apneic oxygenation for intubation under general anesthesia. Hypoxemia is prone to occur during anesthesia induction, which can lead to severe complications. Apneic oxygenation is an important method to prolong the safe apnea time, but existing oxygen delivery modalities have limitations in applicability. Although the laryngeal oxygen delivery approach combined with video laryngoscopy has theoretical advantages, clinical evidence is insufficient. Therefore, this study was conducted.
Conditions
- Apneic Oxygenation
Interventions
control group (Group C)Procedure
Before surgery, all participants received a radial arterial line. At arrival to the operating theatre, ECG, invasive arterial blood pressure, pulse oximetry, and train-of-four monitoring were applied. An i.v. line was secured, and a standard infusion of electrolyte solution was started. Participants were then placed supine, in a 10 degrees reverse Trendelenburg position. Preoxygenation was then perform using atight fitting face mask and having each subject breathe 100% O2 at 15 L/min.Tracheal intubation was thereafter performed using a video laryngoscope when the anaesthetist assessed the conditions as appropriate in the control group (Group C).The correct placement of the tracheal tube was confirmed visually by the anaesthetist in charge and a member of the study team. The tracheal tube was secured, and the participant was left apnoeic with the tracheal tube open to the atmosphere until the peripheral oxygen saturation declined to 93% or apnoea is sustained for 5 minutes.
The continuous laryngeal oxygen supply group (Group B)Device
The continuous laryngeal oxygen supply group (Group B) used the same preoxygenation and anesthesia induction methods as the control group. When intubation conditions were assessed to be met, laryngoscopy was performed to evaluate the airway. If the laryngoscopic view was Cormack and Lehane grade 3 or grade 4, the subject was excluded from the study and tracheal intubation was performed. Otherwise, continuous laryngeal oxygen supply was initiated through a modified disposable video laryngoscope blade, which has an internal lumen. The distal end of the blade is connected to an oxygen delivery tube, and the other end of the oxygen delivery tube is connected to a flowmeter, with an oxygen flow rate of 10 L/min to maintain a continuous oxygen supply to the larynx. Upon reaching an SpO2 of 93% or apnoea is sustained for 5 minutes, tracheal intubation and mechanical ventilation was commenced, and the protocol was terminated.
Primary outcomes
What the sponsor says the trial is designed to measure.
- arterial partial pressure of oxygen (PaO2) at 3 minTime frame: 3 minutes after intubation
Locations
No sites are listed on the registry yet.
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.