Device Trial Radar · NCT07660328
Hand Function Outcome After the Application of Transfer Energy Capacitive and Resistive on Post-burn Patients Presented With Carpal Tunnel Syndrome
Last checked: Nov 19, 2026Latest source record: Oct 28, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
52
Planned (sponsor's estimate)
Start
Aug 9, 2026
Primary completion
Oct 30, 2026
Study completion Dec 1, 2026
Sponsor
- Lead sponsor
- Cairo UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jun 22, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Single (investigator)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 20 years, up to 40 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Carpal Tunnel Syndrome (CTS) is a common entrapment neuropathy that can develop as a secondary complication following deep burns involving the hand or wrist. Post-burn CTS arises due to factors such as fibrosis, edema, and scar contracture, which may increase pressure on the median nerve within the carpal tunnel, leading to significant pain, sensory disturbances, and impaired hand function Recent studies support the effectiveness of Transfer Energy Capacitive and Resistive (TECAR ) therapy in idiopathic CTS, showing improvements in pain, symptom severity, and function, as measured by validated tools such as the Boston Carpal Tunnel Questionnaire (BCTQ) and Visual Analogue Scale (VAS). A study reported that both TECAR and ultrasound groups showed significant symptom improvement after treatment, although ultrasound had more sustained effects on median nerve cross-sectional area at 3 months
Conditions
- Carpal Tunnel Syndrome (CTS) Post-burn
Interventions
Transfer Energy Capacitive and Resistive (TECAR) [ SMART TECAR }Device
TECAR therapy at a frequency of 0.5 MHz and intensity of 30 to 50% and medium Capacitive Energy Transfer electrode (60 mm), 5 min capacitive (CAP) and 10 min resistive (RES), The passive electrode was fixed to the dorsum of the hand while the active electrode was moved in a circular manner from the proximal carpal tunnel to the median nerve pathway of the palm in three sessions per week for two weeks
Standard Hand Rehabilitation [ US }Other
US using a 3 MHz probe at a dose of 1.5 watts/cm2 for 5 min intermittently for 2 weeks, 5 times a week, plus mobility and strengthening exercises
Primary outcomes
What the sponsor says the trial is designed to measure.
- Symptom SeverityTime frame: Baseline and 2 weeks
- Functional StatusTime frame: Baseline and 2 weeks.
- Grip StrengthTime frame: Baseline and 2 weeks.
Locations
1 site in 1 country. Site status is shown where the registry gives one.
QWAM physio clinic
Al Mansurah, Mansoura, Egypt · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.