All In MedTech

Device Trial Radar · NCT07635602

Data Collection Study Using CS BP Pillow System

A Data Collection Study to Collect Blood Pressure Data Using the CardiacSense BP Pillow System for Algorithm Development

Last checked: Nov 19, 2026Latest source record: Aug 4, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

50

Actual

Start

Feb 10, 2026

Primary completion

Apr 30, 2026

Study completion Apr 30, 2026

Sponsor

Lead sponsor
CardiacSense Ltd.Not on our public-company list
Sponsor type
Industry
First posted
Jun 9, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Other
FDA-regulated device
Yes
Who can join
All sexes, from 20 years, up to 80 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

Collect raw data from CS BP Pillow System ,CS BP Plate System, IR (Infrared) PPG (Photoplethysmography) sensors and Arterial line (A-line) in volunteers. The data collected in the study will be used for development of the CS BP algorithms.

Conditions

  • Blood Pressure Monitoring

Interventions

  • CS BP Pillow System, CS BP Plate System and IR PillowsDevice

    Device: CS Pillow System CS Pillow System estimates blood pressure using ECG and tonometry signals. It includes a tonometry sensor embedded in a biocompatible pillow, positioned over the radial artery with a wristband for improved sensitivity and comfort and ECG chest wet electrodes fitted on the torso. CS BP Plate System estimates blood pressure using ECG and PPG. The system consists of a handheld, battery-operated Plate with integrated optical and ECG sensors contacted by the thumb. Infrared (IR) Pillow contain a PPG sensor (IR LED and photodiode) embedded in a biocompatible "pillow. The IR Pillow is placed over the radial artery. This sensor enables estimation of arterial compliance, an important factor influencing the blood pressure-blood volume relationship. Data collected using the CS BP Pillow System and the CS Plate System will be compared to data collected using Arterial Line.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Number of subjects with complete protocol-defined multi-modal physiological signal acquisitionTime frame: day 1, 1 hour

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Element Boulder Avista Adventist Hospital Plaza

    Louisville, Colorado

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.