All In MedTech

Device Trial Radar · NCT07608380

Accuracy of Positioning Guide and Customized Plate in Zygomaticomaxillary Complex Fracture

Accuracy of Positioning Guide and Customized Titanium Plate for Reduction and Fixation of Zygomaticomaxillary Complex Fracture: A Case Series

Last checked: Nov 21, 2026Latest source record: Nov 4, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Enrolling by invitation

Status

Enrolling by invitation

Enrollment

8

Planned (sponsor's estimate)

Start

Dec 18, 2025

Primary completion

Dec 1, 2026

Study completion Sep 1, 2027

Sponsor

Lead sponsor
Cairo UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
May 27, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This prospective, single-arm case series aims to evaluate the accuracy of a virtual planning-based positioning guide and customized titanium plate for the reduction and fixation of unilateral zygomaticomaxillary complex (ZMC) fractures. The primary objective is to assess fracture reduction accuracy by comparing postoperative CT findings with the preoperative virtual surgical plan. Secondary objectives are to evaluate fixation stability and patient satisfaction. Participants undergo preoperative CT imaging for virtual surgical planning, followed by surgical reduction and fixation using a patient-specific positioning guide and customized titanium plate. Postoperative CT imaging is used to assess reduction accuracy, with subsequent follow-up to evaluate fixation stability and patient satisfaction.

Conditions

  • Zygomaticomaxillary Complex Fracture
  • Zygoma Fracture
  • Zygomatic Fractures

Interventions

  • Patient-specific positioning guideDevice

    A 3D-printed positioning guide designed through virtual surgical planning to assist in the accurate reduction of ZMC fractures.

  • Customized titanium plateDevice

    A custom-fabricated titanium plate designed to fit the patient's specific anatomy for rigid fixation of ZMC fractures.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Accuracy of Fracture ReductionTime frame: one week postoperative

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • department of oral and maxillofacial surgery, faculty of dentistry, Cairo university

    Cairo, Egypt

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.