Device Trial Radar · NCT07608380
Accuracy of Positioning Guide and Customized Plate in Zygomaticomaxillary Complex Fracture
Last checked: Nov 21, 2026Latest source record: Nov 4, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Enrolling by invitation
Enrollment
8
Planned (sponsor's estimate)
Start
Dec 18, 2025
Primary completion
Dec 1, 2026
Study completion Sep 1, 2027
Sponsor
- Lead sponsor
- Cairo UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- May 27, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This prospective, single-arm case series aims to evaluate the accuracy of a virtual planning-based positioning guide and customized titanium plate for the reduction and fixation of unilateral zygomaticomaxillary complex (ZMC) fractures. The primary objective is to assess fracture reduction accuracy by comparing postoperative CT findings with the preoperative virtual surgical plan. Secondary objectives are to evaluate fixation stability and patient satisfaction. Participants undergo preoperative CT imaging for virtual surgical planning, followed by surgical reduction and fixation using a patient-specific positioning guide and customized titanium plate. Postoperative CT imaging is used to assess reduction accuracy, with subsequent follow-up to evaluate fixation stability and patient satisfaction.
Conditions
- Zygomaticomaxillary Complex Fracture
- Zygoma Fracture
- Zygomatic Fractures
Interventions
Patient-specific positioning guideDevice
A 3D-printed positioning guide designed through virtual surgical planning to assist in the accurate reduction of ZMC fractures.
Customized titanium plateDevice
A custom-fabricated titanium plate designed to fit the patient's specific anatomy for rigid fixation of ZMC fractures.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Accuracy of Fracture ReductionTime frame: one week postoperative
Locations
1 site in 1 country. Site status is shown where the registry gives one.
department of oral and maxillofacial surgery, faculty of dentistry, Cairo university
Cairo, Egypt
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.