Device Trial Radar · NCT07587437
Preoperative Use of a Magnetically Controlled Capsule Endoscopy in Patients Undergoing Bariatric Surgery
Last checked: Nov 19, 2026Latest source record: May 14, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Enrolling by invitation
Enrollment
30
Planned (sponsor's estimate)
Start
Aug 1, 2025
Primary completion
Dec 30, 2026
Study completion Jan 30, 2027
Sponsor
- Lead sponsor
- Jerry DangAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- The Cleveland Clinic; AnX Robotica Corp.
- First posted
- May 14, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Diagnostic
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The goal of this clinical trial is to test if a swallowable camera capsule can safely examine the upper digestive tract in people preparing for weight loss surgery. The camera capsule (called NaviCam® Xpress™ Stomach System) is controlled by magnets from outside the body and doesn't require sedation, unlike traditional endoscopy. The main questions it aims to answer are: Can the camera capsule be safely used in people with a body mass index (BMI) greater than 38? Can doctors successfully control and move the camera capsule to see the necessary areas of the stomach and esophagus? Researchers will evaluate 30 participants who are preparing for weight loss surgery. Participants will: Swallow the camera capsule with water after not eating or drinking since midnight Have their upper digestive tract examined while the doctor controls the capsule from outside their body Complete a brief satisfaction survey about their experience Be followed up with a phone call 2-3 weeks after the procedure This study could help determine if the camera capsule is a good alternative to traditional endoscopy for people preparing for weight loss surgery, potentially avoiding the need for sedation.
Conditions
- Obesity
- Bariatric Surgery Candidate
- Hypertension
- Diabetes
Interventions
Magnetically Controlled Capsule Endoscopy (MCCE)Device
The intervention consists of a wireless capsule containing cameras and magnetic materials that enable external control. After overnight fasting, participants swallow the capsule with 500ml of water. The capsule is initially tethered and captures images as it descends the esophagus. Once appropriately positioned, the tether is released by injecting 15ml of air. A trained surgeon then controls the capsule's movement within the stomach using an external magnetic control system, allowing systematic visualization of the upper gastrointestinal tract mucosa. The procedure is performed without sedation and takes place at the Main Campus M60 facility. The capsule naturally passes through the digestive system after the examination.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Number of Participants with Successful Magnetic Control of the CapsuleTime frame: From enrollment to the end of interpretation of the MCCE images, approximately 20 days.
- Number of Participants with Adequate Visualization of the Esophageal and Gastric MucosaTime frame: From enrollment to the end of interpretation of the MCCE images, approximately 20 days.
- Number of Participants Completing MCCE Without Conversion to Conventional EndoscopyTime frame: From enrollment to the end of interpretation of the MCCE images, approximately 20 days.
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Cleveland Clinic Foundation
Cleveland, Ohio
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.