All In MedTech

Device Trial Radar · NCT07569575

Magnesium-Titanium Hybrid Intramedullary Nail System For Long Bone Fractures

A Prospective, Multicenter, Randomized, Controlled, Non-inferiority Clinical Trial to Evaluate the Safety and Effectiveness of the Magnesium-titanium Hybrid Intramedullary Nail System in Treating Long Bone Fractures of the Extremities

Last checked: Nov 19, 2026Latest source record: Nov 3, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruitingPivotal-lookingRandomized with 160 participants. This is a heuristic, not a regulatory label.

Status

Not yet recruiting

Enrollment

160

Planned (sponsor's estimate)

Start

Nov 1, 2026

Primary completion

Mar 31, 2028

Study completion Dec 31, 2028

Sponsor

Lead sponsor
HuaMg Perfection Med Tech (Suzhou) Co., Ltd.Not on our public-company list
Sponsor type
Industry
First posted
May 6, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 80 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This is a prospective, multicenter, randomized, controlled, non-inferiority clinical trial designed to evaluate the safety and effectiveness of the magnesium-titanium hybrid intramedullary nail system compared with the marketed metal locked intramedullary nail in the treatment of long bone fractures of the extremities.

Conditions

  • Tibial Fracture
  • Femoral Fracture
  • Humeral Fracture

Interventions

  • Magnesium-Titanium Hybrid Intramedullary Nail SystemDevice

    The magnesium-titanium hybrid intramedullary nail system is inserted into the medullary canal through the proximal or distal end of the bone via standard intramedullary fixation surgical procedures, achieving fixation of the fracture site through intramedullary stabilization. This device provides load-sharing fixation for the fracture. The titanium alloy main body of the product delivers continuous, reliable mechanical support to ensure the overall stability of fracture fixation. The biodegradable magnesium components gradually degrade in vivo, releasing magnesium ions that participate in regulating the local bone repair microenvironment, thereby synergistically supporting the fracture healing process.

  • Commercially Locked Metallic Intramedullary NailDevice

    Commercially available metallic intramedullary nails including the humeral intramedullary nail (NMPA Registration No. 20233130578) and locked intramedullary nail (NMPA Registration No. 20163131478) manufactured by Shandong Weigao Orthopaedic Device Co., Ltd. are selected as the control devices based on the following reasons: 1) Shandong Weigao Orthopaedic Device Co., Ltd. is a leading orthopaedic enterprise in China, and its products are widely used in clinical practice with well-established efficacy and safety profiles; 2) The indications of the control devices fully cover those of the investigational device.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Effective rate of the product at 180 days postoperativelyTime frame: 180±14 days postoperatively

Locations

5 sites in 1 country. Site status is shown where the registry gives one.

  • Beijing Jishuitan Hospital, Capital Medical University

    Xicheng, Beijing Municipality, China

  • Henan Luoyang Orthopedic Hospital (Henan Orthopedic Hospital)

    Luoyang, He'Nan, China

  • Hebei Medical University Third Hospital

    Shijiazhuang, Hebei, China

2 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.