Device Trial Radar · NCT07546877
High-Frequency Repetitive Transcranial Magnetic Stimulation for Cognitive Improvement in Patients With Post-Stroke Cognitive Impairment
Last checked: Nov 19, 2026Latest source record: Nov 12, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
40
Planned (sponsor's estimate)
Start
Apr 1, 2026
Primary completion
Jul 1, 2027
Study completion Jul 1, 2027
Sponsor
- Lead sponsor
- Qilu Hospital of Shandong UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Apr 23, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Double (participant, outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 35 years, up to 75 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
To clarify the clinical efficacy of high-frequency rTMS on patients with post-stroke cognitive impairment, fNIRS and EEG techniques were used to observe the changes in brain functional activities of patients with post-stroke cognitive impairment after rTMS treatment, and to clarify the neuroregulatory effect of rTMS on patients with post-stroke cognitive impairment.
Conditions
- Post-Stroke Cognitive Impairment (PSCI)
- Repetitive Transcranial Magnetic Stimulation (rTMS)
- Stroke
Interventions
sham repetitive transcranial magnetic stimulationOther
The control group will undergo rTMS sham stimulation therapy combined with conventional rehabilitation treatment. They will use a sham stimulation coil, which means applying the same parameters and methods to stimulate the head. Although the sham stimulation coil has no difference in appearance and sound from the real stimulation coil, it cannot generate a real magnetic field to stimulate the brain.
repetitive transcranial magnetic stimulationDevice
The stimulation site is the dorsolateral area of the left prefrontal lobe. The "8" shape coil is placed in contact with the scalp. The frequency is 10Hz, the repetition rate is 80% rMT. The stimulation lasts for 5 seconds, with an interval of 25 seconds. A total of 40 sets of stimulation are given, with a total of 2000 pulses. The treatment lasts for 20 minutes per day, for 20 days in total. A total of 20 interventions were completed. The experimental group will receive rTMS stimulation therapy, which involves applying high-frequency 10Hz rTMS to the patients' heads for 20 minutes, followed by conventional rehabilitation treatment.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Montreal Cognitive AssessmentTime frame: Baseline, Day 10, Day 20,Evaluate the Montreal Cognitive Assessment Scale, fNIRS, Symbol-Digit Substitution Test, Shape Linking Test, Pittsburgh Sleep Quality Index, Digit Span Test, Stroop Test, Fugl-Meyer Assessment, Hamilton Depression Scale, Hamilton
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Qilu Hospital of Shandong University
Jinan, China · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.