All In MedTech

Device Trial Radar · NCT07543406

MINDZ-- Minimally Invasive Approach Pilot Study

MINDZ-- Minimally Invasive Approach Pilot Study Single Center, First-in-Human Evaluation of MINDZ Electrode- Demonstrating the Feasibility of Burr-hole Deployment and Functional Efficacy

Last checked: Nov 19, 2026Latest source record: Sep 10, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruiting

Status

Not yet recruiting

Enrollment

5

Planned (sponsor's estimate)

Start

Oct 1, 2026

Primary completion

Sep 1, 2027

Study completion Sep 1, 2027

Sponsor

Lead sponsor
Neurosoft Bioelectronics SANot on our public-company list
Sponsor type
Industry
First posted
Apr 21, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Device feasibility
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 75 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This clinical investigation is a pilot, first-in-human (FIH) study designed to demonstrate proof of concept, safety, and functional performance of the MINDZ subdural electrode grid when used in relevant neurosurgical settings. The study will provide initial clinical evidence to support future conformity assessment and CE marking under the European Medical Device Regulation (MDR). The investigational device, MINDZ, developed by Neurosoft Bioelectronics, is a novel, soft and highly conformable subdural electrode grid designed for minimally invasive implantation through a burr hole. Its flexible structure is intended to improve conformity to the cortical surface, reduce dead space between the electrode and brain tissue, and potentially lower the risk of complications associated with craniotomy, while maintaining adequate cortical coverage for effective monitoring and mapping.

Conditions

  • Intraoperative Neurophysiological Monitoring

Interventions

  • MINDZ Subdural Electrode GridDevice

    The study intervention is limited to the insertion of the investigational device through the burr hole (up to 15 minutes), followed by an additional 5-minute recording using the device, resulting in a total extension of approximately 20 minutes to the standard surgical procedure. The data recorded using the investigational device will not be used for clinical decision-making. Following completion of the recording, the device will be removed through the burr hole, and the surgery will proceed according to the standard clinical protocol.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Safety of the MINDZ Subdural Electrode GridTime frame: during the intraoperative procedure and up to 30days follow up
  2. Functional Performance of the MINDZ Subdural Electrode GridTime frame: during the intraoperative procedure (post-deployment)

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • University Hospital Zurich

    Zurich, Switzerland

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.