Different Laser Frequencies on Neuropathic Outcomes in Patients With Bell's Palsy

Last checked: Nov 20, 2026Latest source record: Aug 20, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedPivotal-lookingRandomized with 104 participants. This is a heuristic, not a regulatory label.

Status

Completed

Enrollment

104

Actual

Start

Dec 1, 2025

Primary completion

May 1, 2026

Study completion Jun 15, 2026

Sponsor

Lead sponsor
Kafrelsheikh UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Apr 9, 2026

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Single (participant)
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

this study was done to compare different laser frequencies on neuropathic outcomes in patients with Bell's palsy.

Conditions

  • Neuropathy, Facial
  • Bell Palsy
  • Laser

Interventions

  • sham laser therapyDevice

    the laser irradiation will be deactivated in the sham laser device by its manufacturer, but its visual light and acoustic functions maintained. The output power of the sham laser's infrared light will be zero mW, will be applied over the eight points over the face

  • Low-Level Laser TherapyDevice

    Low-Level Laser Therapy (LLLT) for 5 min over eight points over the face, with the laser probe in direct contact with the superficial roots of the facial nerve. The parameters will be used wavelength of 808 nm (Polaris HP, Astar, Bielsko-Biała, Poland) and 980 nm (TheraLASER max, TheraMarkt, Germany), frequency of 1 kilohertz, the duty cycle of 80%, and energy density of 10 J/cm'. During each session, the total energy will be delivered to the patient are 1440 J per session (8 treatment points × 180 J per point; 3 W average power over a 6 cm² applicator, 60 s per point).

  • gallium arsenide diode laser (BTL-5000 laser)Device

    gallium arsenide diode laser (BTL-5000 laser) will be used with infrared probes of 830 nm wavelength and 100 mW output power, average energy density of 10 J/em?, a frequency of 1 kilohertz, and a duty cycle of 80 %. In all cases, the laser will be in direct contact with the superficial roots of the facial nerve on the affected side and will be applied for 2 min and 5 s per point for 8 points with a total energy of 1440 J per session (8 treatment points × 180 J per point; 3 W average power over a 6 cm² applicator, 60 s per point)

  • high intensity laser treatmentDevice

    High intensity laser therapy treatment with pulsed neodymium doped: yttrium aluminum garnet laser. The apparatus provided the following options: pulsed emission (1,064 nm), very high peak powers (3 kW), high levels of fluency (energy density) (810-1,780 mJ/cm), brief duration (120-150 Ms), low frequency (10-40 Hertz), and a duty cycle of approximately 0.1 %. High intensity laser therapy will be applied with contact and perpendicular to the superficial roots of the facial nerve of the affected side. The time of application will be 7 s/per point with an energy density of 10 J/em'. The total energy delivered to the patient during one session will be 1440 J per session (8 treatment points × 180 J per point; 3 W average power over a 6 cm² applicator, 60 s per point). The device calculates the number of pulses, energy received for each session, and the total energy delivered to the patient during the treatment session

  • ExercisesOther

    Patients in all treatment groups received the same standardized rehabilitation programme consisting of facial massage, mirror exercises, and resisted facial and neck exercise

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. assessment of Compound motor action potential of facial nerveTime frame: at baseline and after 6 weeks

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • outpatient clinic, Department of physical therapy at King Fahd Hospital in Almadinah Almunawwarah.

    Madinah, Saudi Arabia

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.