All In MedTech

Device Trial Radar · NCT07436247

Pseudophakic Eyes With Presbyopia-correcting IOLs: OCT Biometry and Pyramid Aberrometry

Pseudophakic Eyes Implanted With Different Presbyopia-correcting IOL Designs: 3-D Anterior Segment OCT Biometry and Pyramid Wavefront Sensing- Based Retinal Image Quality

Last checked: Nov 19, 2026Latest source record: Feb 27, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

80

Planned (sponsor's estimate)

Start

Apr 4, 2024

Primary completion

Apr 1, 2026

Study completion Jul 1, 2026

Sponsor

Lead sponsor
Prim. Prof. Dr. Oliver Findl, MBAAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Feb 27, 2026

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
All sexes, from 21 years, up to 110 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

To correlate ocular morphology from anterior segment OCT and pyramid wavefront sensing in order to comprehensively analyze pseudophakic in vivo image quality of presbyopia-correcting IOLs in cataract patients.

Conditions

  • Cataract

Interventions

  • Osiris-T Pyramid Wavefront Sensor - (CSO, Italy)Device

    The Osiris-T aberrometer is a CE-certified device that operates via a high-resolution four-faced pyramid wavefront sensor (PWS) to analyze light intensity among four images (sub-apertures) of the patients ́entrance pupil akin to a Foucault knife-edge test. Thereby measurements of the wavefront and refractive error can be quantified non-invasively. The sampling density of the wavefront error is 45,000 points at maximum pupil. The device uses a near-infrared extended light-emitting diode source emitting at 850 nm. Its is additionally intertwined with a corneal topography system to also characterize the corneal aberrations and compute via direct subtraction the internal ocular optics.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. IOL ocular optics measumentTime frame: 24 months

Locations

2 sites in 1 country. Site status is shown where the registry gives one.

  • Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna

    Vienna, Austria · Recruiting

  • Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna

    Vienna, Austria · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.