Leica Microsystems Sponsored PMCF Study to Collect and Confirm Clinical Data on the Performance of the GLOW400 Device When Used in Accordance With Its Intended Use
Last checked: Nov 20, 2026Latest source record: Nov 3, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
37
Planned (sponsor's estimate)
Start
Apr 28, 2026
Primary completion
Feb 28, 2027
Study completion Aug 31, 2027
Sponsor
- Lead sponsor
- Leica Microsystems (Schweiz) AGNot on our public-company list
- Sponsor type
- Industry
- First posted
- Jan 26, 2026
Design
- Study type
- Observational
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This post-market clinical follow-up (PMCF) study aims to confirm the safety and performance of the GLOW400 surgical microscope accessory when used in conjunction with the ARveo8x surgical microscope. The study evaluates fluorescence visualization and image quality during standard surgical procedures in neurosurgery. It is a non-interventional, observational study conducted in routine care settings across multiple European sites.
Conditions
- Suspected Grade III and IV Gliomas Requiring Surgical Intervention
- Neurosurgical Procedure
- Glioma
- Glioblastoma (GBM)
Interventions
GLOW400 is a digital surgical microscope accessory used in fluorescent visualization of suspected grade III or IV gliomas during neurosurgery.Device
The digital surgical microscope accessory GLOW400 is using the optical excitation and emission filtering of the FL400. The FL400 provides an illumination filter (380nm - 430nm) which when engaged into the light source path of the surgical operating microscope provides, via a light guide, a fluorescence excitation light system used in conjunction with an approved tumor-selective substance (fluorophore) (e.g. Protoporphyrin IX (PpIX) which is resulting of the metabolization of 5-ALA (5 - aminolaevulinic acid)) for tissue characterization in the open neurosurgery field. PpIX is strongly fluorescent with a peak at λ=635 nm as red-violet after excitation with blue light (λ=380-410 nm). The digital surgical microscope accessory GLOW400 is using the optical excitation and emission filtering of the FL400. The fluorescence signal visualized depicts the distribution of the dye in the patient's tissues during the surgical procedure.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Flourescence visibilityTime frame: Periprocedural
- Image qualityTime frame: Periprocedural
- Anatomy of the brain, including Vessels (GLOW400 Anatomy only)Time frame: Periprocedural
Locations
2 sites in 2 countries. Site status is shown where the registry gives one.
Unidade Local de Saúde de São João
Porto, Portugal · Recruiting
University Hospital Basel
Basel, Switzerland · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.