Device Trial Radar · NCT07356401
Associations of Cranial Outcomes and Parental Expectations and Satisfaction
Last checked: Nov 19, 2026Latest source record: Sep 11, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
10
Actual
Start
Nov 25, 2025
Primary completion
Feb 15, 2026
Study completion Mar 15, 2026
Sponsor
- Lead sponsor
- Gulhane School of MedicineAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jan 21, 2026
Design
- Study type
- Observational
- FDA-regulated device
- No
- Who can join
- All sexes, from 3 months, up to 18 months
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This study aims to investigate the association between objective cranial morphological changes and parental expectations and satisfaction in infants undergoing treatment with a cranial remolding orthosis (CRO). Infants diagnosed with positional cranial deformities and prescribed CRO treatment will be included. Cranial morphological outcomes will be assessed using standardized cranial measurements obtained before and after the treatment period. Parental treatment expectations will be evaluated prior to the initiation of CRO therapy using the Treatment Expectation Questionnaire (TR.TEX-Q), while parental satisfaction with the device and treatment process will be assessed at the end of treatment using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST). The primary objective of the study is to examine the relationships between changes in cranial morphology and parental expectations and satisfaction scores. Secondary objectives include exploring the association between baseline expectations and post-treatment satisfaction. The findings are expected to provide insight into how objective treatment outcomes align with family-reported perceptions in cranial remolding orthosis therapy.
Conditions
- Plagiocephaly
- Cranial Defect
- Orthosis
- Expectancy
- Satisfaction
Interventions
Cranial orthosisDevice
The intervention consisted of treatment with a custom-fabricated cranial remolding orthosis (CRO). Each orthosis was individually designed based on the infant's cranial shape using three-dimensional cranial scanning and computer-aided modeling. A mold was produced using CNC technology, and a thermoplastic material was formed over the mold to create the final orthosis. The fabricated CRO was delivered to the clinic within a few days and fitted to the infant. During the initial fitting, the orthosis was clinically inspected for proper fit and for any signs of skin redness, irritation, or pressure-related issues. Necessary adjustments were made, and parents were provided with detailed instructions regarding orthosis use and care. Infants were subsequently scheduled for regular clinical follow-up, and only custom-fabricated cranial remolding orthoses were included in the study.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Change in cranial morphological measurements following cranial remolding orthosis treatmentTime frame: Periprocedural
- Parental treatment expectationsTime frame: baseline
Locations
1 site in 1 country. Site status is shown where the registry gives one.
University of Health Sciences Gülhane Faculty of Health Sciences
Ankara, Keçiören, Turkey (Türkiye)
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.