Device Trial Radar · NCT07350187
Prospective, Randomized, Controlled Trial Comparing Self-Gripping and Conventional Mesh in Laparoscopic Totally Extra Peritoneal Inguinal Hernia Repair
Last checked: Nov 19, 2026Latest source record: Jan 20, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
95
Actual
Start
Oct 22, 2024
Primary completion
Oct 14, 2025
Study completion Oct 14, 2025
Sponsor
- Lead sponsor
- Chungnam National University HospitalAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jan 20, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Double (participant, care provider)
- Primary purpose
- Other
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 19 years, up to 100 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This study is a single-center, prospective, randomized controlled trial designed to compare clinical outcomes between self-gripping mesh and conventional mesh with limited tacker fixation in laparoscopic totally extraperitoneal (TEP) inguinal hernia repair. Adult patients diagnosed with inguinal hernia and scheduled for laparoscopic TEP repair are randomly assigned to receive either a self-gripping mesh (Progrip™) or a conventional mesh fixed with a single permanent tacker to the pubic bone (Parietex™). Both meshes are commonly used in clinical practice and approved for inguinal hernia repair. The primary objective of this study is to evaluate postoperative discomfort and quality of life following surgery. Outcomes are assessed using validated patient-reported questionnaires, including the Carolina Comfort Scale (CCS) and the International Prostate Symptom Score (IPSS). Secondary outcomes include postoperative complications, physical examination findings such as local induration or tenderness, operative time, and short-term hernia recurrence. Patients are followed at 1 week, 3 weeks, and 3 months after surgery. The results of this study aim to provide comparative evidence regarding the safety and short-term clinical outcomes of self-gripping versus tacker-fixed conventional mesh in laparoscopic TEP inguinal hernia repair.
Conditions
- Inguinal Hernias
Interventions
Self-gripping mesh (Progrip™)Device
self-gripping surgical mesh used during laparoscopic totally extraperitoneal (TEP) inguinal hernia repair. The mesh adheres to surrounding tissue via resorbable microgrips and does not require additional fixation devices.
Conventional mesh with tacker fixation (Parietex™)Device
A conventional surgical mesh used during laparoscopic totally extraperitoneal (TEP) inguinal hernia repair. The mesh is fixed with a single permanent tacker placed on the pubic bone to ensure mesh stability.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Postoperative discomfort assessed by the Carolina Comfort Scale (CCS)Time frame: From baseline to 1 week and 3 months after surgery
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Chungnam National University Hospital
Daejeon, South Korea
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.