Device Trial Radar · NCT07338994
TENS With Proprioceptive-Visual Training on Gait Parameters in CP
Last checked: Nov 19, 2026Latest source record: Jan 14, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
30
Actual
Start
Apr 10, 2025
Primary completion
Jul 20, 2025
Study completion Sep 1, 2025
Sponsor
- Lead sponsor
- Cairo UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jan 14, 2026
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Double (participant, investigator)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 4 years, up to 6 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
This study aimed to evaluate the effect of TENS with proprioceptive - visual training on gait parameters in children with spastic diplegic cerebral palsy.
Conditions
- Cerebral Palsy (CP)
Interventions
TENSDevice
Electrical stimulation will be delivered by means of self-adherent surface electrodes (Encore plus), using a programmable electrical stimulator, providing monophasic rectangular pulse trains. Electrodes were attached over the belly of the rectus femoris and tibialis anterior muscles. The quadriceps and the dorsiflexors were selected due to their dominance in establishing a normal and efficient gait. TENS was applied for 20 minutes during gait training. The parameters selected for the electrical stimulation will be as follows: frequency 20Hz, pulse-width 0.25 msec, and intensity will be individually adjusted for each subject
1. Tekscan Walkway systemDevice
It includes sensors (4 sensels/cm2) with a resolution of up to 185 Hz, a digital mat (195.5 cm long by 44.2 cm wide) placed in a wooden pathway, and a pressure sensor (1 to 862 kPa). The plasma screen faces the walkway and is 1.5 meters high and 7 meters away. It displays pictures that are mirrored from seven pressure points (forming the contour of the foot). if the foot's heel, midfoot, forefoot, fifth metatarsal, third-fourth, second, and first metatarsals are the seven areas of pressure. Data such as maximum peak pressure (kPa), stance time (s), cadence, gait time (s), distance (cm), velocity (cm/s), and transmission hardware (cable and sensor-interface or so-called handle) will be extrapolated using a computer running The Tekscan Software (version 7).
Primary outcomes
What the sponsor says the trial is designed to measure.
- cadenceTime frame: 8 weeks
- step length and widthTime frame: 8 weeks
- gait velocityTime frame: 8 weeks
2 more outcomes with a free account
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Cairo university
Giza, Egypt
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.