Device Trial Radar · NCT07301749
A Clinical Study Evaluating the Safety and Efficacy of the VCFix Spinal System for Treatment of Vertebral Compression Fractures
Last checked: Nov 19, 2026Latest source record: Jun 22, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
148
Planned (sponsor's estimate)
Start
Nov 4, 2025
Primary completion
Jul 31, 2027
Study completion Dec 31, 2029
Sponsor
- Lead sponsor
- Amber Implants B.V.Not on our public-company list
- Sponsor type
- Industry
- First posted
- Dec 24, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Non randomized
- Model
- Parallel
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 21 years, up to 85 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This study is being conducted to evaluate the safety and performance of the VCFix Spinal System, a medical device designed to treat certain types of spinal fractures called vertebral compression fractures (VCFs) in adults. Up to 8 hospitals in Europe will take part in the study. All participants will receive treatment with the VCFix device. The treatment will be provided according to the intended use of the device and may be performed either with or without the use of a special bone cement. Participants will be assigned to one of two study groups before treatment: Cementless group: the VCFix device is implanted without bone cement. Cemented group: the VCFix device is implanted together with bone cement. The study will assess how well the treatment works and how safe it is. Researchers will evaluate: Changes in back pain 6 months after treatment compared with before treatment. Changes in daily functioning and ability to perform everyday activities 6 months after treatment compared with before treatment. Whether any serious device-related complications occur during the first month after treatment. The results will help determine whether treatment with the VCFix device provides benefits for patients with vertebral compression fractures while maintaining an acceptable safety profile.
Conditions
- Vertebral Compression Fracture
Interventions
VCFix Spinal System in stand-alone configurationDevice
The distinguishing features of this inetrvention reside in: 1. In situ adjustment and maintenance of the height and angle of the device that allows expansion of the fractured VB in the cranio-caudal direction to realign the vertebral endplates and correct kyphosis. 2. The complex titanium perforated structure with optimized surface roughness that allows possible bone attachment, thereby permitting natural healing of the bone and potentially providing more stability to the device and the treated vertebra over time. 3. The ability to likely secure and reinforce the vertebra without using PMMA bone cement, avoiding all the symptomatic and asymptomatic side effects of bone cement. 4. The ability to connect the posterior to the anterior column of the spine through the pedicle screw component of the VCFix implant, therefore improving the biomechanical load distribution and consequently the ability to stabilize more severe fractures.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Reduction of more than 2 points in vertebral fracture-related pain intensity at 6 months after the index procedure compared to baseline as measured by a 11-point Numerical Pain Rating Scale (NPRS)Time frame: 6 months
- Maintenance or improvement of function as measured by the 100-point Oswestry Disability Index (ODI) at 6 months compared to baselineTime frame: 6 months
- Absence of serious adverse device effects (SADEs): No SADEs with causality rated as definite, monitored through 1 month post-procedure (safety)Time frame: 1 month
Locations
3 sites in 2 countries. Site status is shown where the registry gives one.
Centre Hospitalier Métropole de Savoie
Chambéry, France · Not yet recruiting
Wilhelmsburger Krankenhaus Groß-Sand
Hamburg, Germany · Recruiting
Krankenhaus Mechernich
Mechernich, Germany · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.