Device Trial Radar · NCT07298356
Automated Applanation Tonometry - Updated
Last checked: Nov 19, 2026Latest source record: Nov 3, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
200
Planned (sponsor's estimate)
Start
Mar 2, 2026
Primary completion
Dec 29, 2026
Study completion Dec 29, 2026
Sponsor
- Lead sponsor
- Duke UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Dec 23, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- None
- Primary purpose
- Diagnostic
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. Another clinical standard for checking eye pressure is known as the pneumotonometer. This method is more objective but not portable. The purpose of this study is to develop new methods of measuring eye pressure that are more objective, reproducible and portable. In this study, the investigators will be comparing the eye pressure measurements using 2 investigational methods to GAT and pneuumotonometer.
Conditions
- Glaucoma
- Glaucoma, Suspect
Interventions
Standard GATDevice
Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice
Fixed force GATDevice
An investigational device similar to standard GAT
Upright applanating prototypeDevice
An investigational device, prism used in standard and fixed-force GAT is attached to a portable device
PneumotonometerDevice
This is a standard for checking eye pressure. A topical anesthetic (numbing agent). A probe will touch the front of the eye while the machine measures the eye pressure
Primary outcomes
What the sponsor says the trial is designed to measure.
- Intraocular pressure (IOP) as measured by standard GATTime frame: Baseline
- Intraocular pressure (IOP) as measured by fixed force GATTime frame: Baseline
- Intraocular pressure as measured by upright applanatingTime frame: Baseline
1 more outcomes with a free account
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Duke Eye Center
Durham, North Carolina · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.