All In MedTech

Device Trial Radar · NCT07230769

Bougie Diameter on Outcomes in Laparoscopic Sleeve Gastrectomy

Impact of Bougie Diameter on Outcomes in Laparoscopic Sleeve Gastrectomy - A Randomized Controlled Trial

Last checked: Nov 19, 2026Latest source record: Feb 18, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

RecruitingPivotal-lookingRandomized with 100 participants. This is a heuristic, not a regulatory label.

Status

Recruiting

Enrollment

100

Planned (sponsor's estimate)

Start

Feb 15, 2026

Primary completion

Dec 2026

Study completion Dec 2026

Sponsor

Sponsor type
Government (non-federal)
First posted
Nov 17, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Triple (participant, care provider, outcomes assessor)
Primary purpose
Prevention
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 70 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Laparoscopic sleeve gastrectomy (LSG) has become an increasingly popular bariatric procedure since its first performance by Hess and Hess in 1988 as a component of the biliopancreatic diversion-duodenal switch (BPD-DS) procedure, which was modified from Scopinaro's biliopancreatic diversion (BPD) and DeMeester's technique. In the early part of the twenty-first century, it was popularized as a first-step intervention before BPD or gastric bypass in the super obese and high-risk group of patients by Regan et al. Due to the unexpected good results in terms of weight loss and resolution of comorbidities, coupled with the simplicity of performing the procedure requiring intervention on only the stomach, sleeve gastrectomy gained status as a stand-alone bariatric procedure as demonstrated by Baltasar et al. The basic principle of LSG is to create a narrow stomach along the lesser curvature, depending on the left gastric artery, using a calibration bougie as a template to perform a vertical partial gastrectomy, resecting the greater curvature and fundus of the stomach according to the International Sleeve Gastrectomy Expert Panel Consensus Statement by Rosenthal et al. The procedure has demonstrated excellent outcomes in terms of weight loss and comorbidity resolution, making it one of the most commonly performed bariatric procedures worldwide according to the IFSO Worldwide Survey by Angrisani et al. Bougie Size Considerations and Rationale The selection of an appropriate bougie size during laparoscopic sleeve gastrectomy represents a critical technical decision that significantly influences both immediate surgical outcomes and long-term patient results. Calibration bougies serve as internal templates to standardize the gastric sleeve diameter and ensure consistent sleeve geometry across different surgeons and institutions, as described by Parikh et al. The diameter of the bougie directly determines the final gastric volume and the degree of restriction achieved, which in turn affects weight loss efficacy, food tolerance, and complication rates. Bougie sizes in current clinical practice typically range from 32-French (Fr) to 50-Fr, with most centers utilizing sizes between 34-Fr and 42-Fr according to the survey by Gagner et al. Small bougie sizes (32-36-Fr) create a more restrictive sleeve with potentially enhanced weight loss but may be associated with increased risks of stenosis, food intolerance, and gastroesophageal reflux disease as reported by Sakran et al. Medium bougie sizes (38-42-Fr) represent a compromise between restriction and safety, offering adequate weight loss while maintaining acceptable complication rates as demonstrated by Weiner et al. Large bougie sizes (44-50-Fr) provide greater sleeve capacity with improved food tolerance and potentially reduced leak rates, though concerns exist regarding long-term weight loss maintenance according to Abdallah et al. The rationale for comparing different bougie sizes stems from the ongoing debate regarding the optimal balance between surgical efficacy and safety. Recent meta-analyses have suggested that larger bougie sizes may be associated with reduced gastric leak rates without significantly compromising weight loss outcomes. However, the majority of existing evidence comes from retrospective observational studies with inherent limitations including selection bias, confounding variables, and lack of standardized outcome measures as noted by Shi et al. The current study aims to provide definitive prospective evidence comparing small (36-Fr) versus X large (larger than 40-Fr) bougie sizes in a randomized controlled trial design. Furthermore, the impact of bougie size on comorbidity resolution remains inadequately studied. Bariatric surgery has demonstrated remarkable efficacy in resolving obesity-related comorbidities, with diabetes remission rates ranging from 53% to 63% as reported by Schauer et al. and hypertension resolution rates varying from 8% to 50% depending on the specific criteria used according to Sjöström et al. The relationship between sleeve geometry, as determined by bougie size, and comorbidity resolution mechanisms requires further investigation to optimize patient outcomes and surgical technique selection.

Conditions

  • Bariatric Sleeve Gastrectomy

Interventions

  • Bougie (>40-Fr)Device

    * Product: MID-TUBE orogastric calibration tube (Médical Innovation Development S.A.S, ref. MID131) * Classification: CE-marked class IIa medical single-use device * Length: 70 cm * Material: Medical silicon rubber, latex-free

  • Bougie (36-Fr)Device

    * Various manufacturers' single-use devices * All devices CE-marked and used per manufacturer instructions * Specific size selection based on center standard care protocols

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Gastric Leak Diagnosis and ClassificationTime frame: within 3 months postoperatively

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • The surgical department of Medical Research Institute Hospital, Alexandria University

    Alexandria, Alexandria Governorate, Egypt · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.