All In MedTech

Device Trial Radar · NCT07215481

Automated Image-Guided Programming of Deep Brain Stimulation (DBS) for Parkinson's Disease

Quantitative Digitography to Evaluate the Efficacy of Image Guided Algorithmic DBS Programming

Last checked: Nov 20, 2026Latest source record: Apr 27, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruiting

Status

Not yet recruiting

Enrollment

15

Planned (sponsor's estimate)

Start

Jun 2026

Primary completion

Jun 2027

Study completion Dec 2027

Sponsor

Lead sponsor
Stanford UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Boston Scientific Corporation
First posted
Oct 10, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 21 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The goal of this clinical trial is to evaluate an automated deep brain stimulation (DBS) algorithm developed by Boston Scientific called Illumina 3D for motor symptoms in Parkinson's disease (PD). The main question it aims to answer is: Is this new automated algorithm effective for treating motor symptoms of PD. Fifteen participants are anticipated to be enrolled. Participants are individuals who recently were implanted with DBS in the subthalamic nucleus as part of their regular clinical treatment and are scheduled to have their DBS turned ON for the first time. In addition to their regular clinical visit when their DBS is turned ON by their clinician, participants are tested on DBS settings determined by Illumina 3D (an automated algorithm). Participants are tested on these different settings across different motor tasks, including walking and finger tapping, as well as answering questionnaires. The experiment is expected to last 1 or 2 days; this is not a longitudinal or long-term trial. Participants return to their usual DBS settings once they leave the clinic.

Conditions

  • Parkinson's Disease (PD)

Interventions

  • Shame Control (Baseline)Device

    Participant's device (Boston Scientific Vercise Genus neurostimulator) is turned off for 45 minutes.

  • Standard of Care Deep Brain StimulationDevice

    Participant's device (Boston Scientific Vercise Genus neurostimulator) is turned 'ON' for 45 minutes using a configuration and amplitude determined as standard of care by the clinician.

  • Illumina 3D Deep Brain StimulationDevice

    Participant's device (Boston Scientific Vercise Genus neurostimulator) is turned 'ON' for 45 minutes using a configuration and amplitude determined by the automated Illumina 3D algorithm.

  • Illumina 3D Deep Brain Stimulation Reduced AmplitudeDevice

    Participant's device (Boston Scientific Vercise Genus neurostimulator) is turned 'ON' for 45 minutes using a configuration and amplitude determined by the automated Illumina 3D algorithm but at a reduced stimulation amplitude.

  • Illumina 3D Deep Brain Stimulation Higher AmplitudeDevice

    Participant's device (Boston Scientific Vercise Genus neurostimulator) is turned 'ON' for 45 minutes using a configuration and amplitude determined by the automated Illumina 3D algorithm but at a higher stimulation amplitude.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change in QDG Mobility Score (OFF DBS to Illumina 3D)Time frame: Baseline and after 45 minutes of Illumina 3D DBS

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Stanford Neuroscience Health Clinic

    Stanford, California

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.